SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 150…350 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 7.5 kW at 660...690 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
7.5 kW at 400...415 V AC 50/60 Hz
9 kW at 400...415 V AC 50/60 Hz
11 kW at 400...415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
11 kW at 500 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
18.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 25 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
CCC
EAC
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.65 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
20000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-2
EN/IEC 60947-4-1
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4L25B - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals is fashioned to cater to the prerequisites of industry specialists, such as control panel builders, electrical installers, management services, and Original Equipment manufacturers. GV4L25B yields remarkable robustness and value for experts in the power engineering industry. This Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are procurable at the most competitive price and delivery schedule through BaltElec, a well-regarded dealer attending to engineers in their collection needs.

Professionals who have acquired Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have consistently extolled the creator's dependability. It has been mentioned that the excellent effectiveness of GV4L25B - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals extends to a variety of purposes. Its superior specifications make it right choice to suit a variety of needs, promoting success in your industrial, tertiary, and automation efforts.

Our team focuses in providing for industrial and tertiary professionals’ needs. We recognize the specific demands and expectations of our stakeholders in the market. By teaming up with our experts, our customers secure access to the best fees and inventory of top-tier products like GV4L25B - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals from Schneider Electric at cost-effective price. Account holders benefit from exclusive discounts and priority service.

Seize the moment and buy GV4L25B - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals at our safe and streamlined platform. Don't delay in making this clever decision that guarantees the best quality and covers the unique expectations of users like your company.

In the event of any matters or concerns about GV4L25B - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals or any other Schneider Electric products, message us or refer to our Knowledge base section below. We have put together answers to standard questions to support you further in making an smart decision about industrial and tertiary electrical components.

Remember, GV4L25B - Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals from Schneider Electric is unfailing, value-priced, and outstanding to market challengers in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your infrastructure at once. Snap up at BaltElec, your dependable vendor for all your professional electrical equipment and automation needs.

In our Baltelec.eu virtual store you will come across Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals - GV4L25B worth 226.62 €, which will be a faithful and current solution for your requirements. This commodity is formulated by the Schneider Electric brand using the freshest technologies and follows the premier standards of guarding and efficacy. We propose goods from the TeSyS Deca GV4 Motor Circuit Breaker category that fuse robustness and workability, which is an top-notch possibility for various tasks. Without consideration of whether you demand devices for small fabrication or for expert industrial application, Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals will be a secure aide in your endeavor.

Baltelec aims to make the securing process as simple and fast as attainable for our users. We offer detailed depictions and high-quality snapshots of Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals so that you can make an well-informed choice. A team of authorities is always ready to help you with any issues in the TeSyS Deca GV4 Motor Circuit Breaker section relevant to the choice and use of articles. We are positive that Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals will meet your expectations and become an necessary element of your equipment for just 226.62 €.

FAQ about Schneider Electric GV4L25B:

Recently viewed
GV4L25B - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, EverLink terminals
185,75 € excl. VAT
230,33 € incl. VAT
Expected in 2-4 weeks