SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 690…1610 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 37 kW at 400...415 V AC 50/60 Hz
45 kW at 400...415 V AC 50/60 Hz
55 kW at 400...415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
75 kW at 660...690 V AC 50/60 Hz
90 kW at 660...690 V AC 50/60 Hz
110 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 115 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
CCC
EAC
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.65 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 10000 cycles for AC-3 at 440 V In/2
5000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals is devised to satisfy the demands of trade professionals, such as system integrators, cable technicians, repair companies, and manufacturing originators. GV4L115N provides extraordinary standards and advantages for consultants in the power engineering industry. This Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be purchased at the most competitive price and supply period through BALTELEC.EU, a credible distributor catering to specialists in their buying needs.

Clients who have opted for Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have consistently complimented the manufacturer’s solidity. It has been outlined that the remarkable effectiveness of GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals extends to a diverse range of purposes. Its elite features make it great selection for various requirements, promoting success in your industrial, tertiary, and automation efforts.

BaltElec devotes in meeting industrial and tertiary professionals’ needs. We understand the customized demands and expectations of our buyers in the sector. By aligning with our experts, your business gain access to the leading costs and inventory of premium products like GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric at a reasonable price. Our registered accounts get further discounts and top-tier service.

Move quickly and acquire GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals at our well-established and easy-to-use webshop. Don't delay in making this wise choice that warrants the supreme quality and addresses the defined demands of vendors like your group.

When you have any doubts or concerns about GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals or any other Schneider Electric products, call us or refer to our Support section section below. We have amassed answers to common matters to facilitate you further in making an smart decision about industrial and tertiary electrical components.

Remember, GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric is credible, low-cost, and outstanding to its competitors in the TeSyS Deca GV4 Motor Circuit Breaker category. Don't hesitate to make it a part of your apparatus promptly. Order at Baltelec e-shop, your dependable vendor for all your TeSyS Deca GV4 Motor Circuit Breaker.

In our Baltelec.eu digital store you will discover Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals - GV4L115N worth 359.13 €, which will be a trustworthy and cutting-edge solution for your requirements. This article is fabricated by the Schneider Electric brand using the most recent technologies and meets the top standards of security and performance. We present things from the TeSyS Deca GV4 Motor Circuit Breaker category that fuse durability and functionality, which is an exceptional preference for various operations. In defiance of whether you demand gear for small output or for competent industrial use, Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals will be a sure facilitator in your duty.

Baltelec strives to make the getting process as convenient and fast as achievable for our shoppers. We offer detailed descriptions and high-quality photos of Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals so that you can make an well-informed choice. A team of connoisseurs is always ready to help you with any issues in the TeSyS Deca GV4 Motor Circuit Breaker section pertaining to the selection and use of commodities. We are convinced that Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals will meet your criteria and become an crucial element of your inventory for just 359.13 €.

What People Ask about GV4L115N - Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals:

Recently viewed
GV4L115N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 115 A, Icu 50 kA, magnetic, EverLink terminals
294,37 € excl. VAT
365,02 € incl. VAT
Expected in 2-4 weeks