SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 42…98 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 7 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
CCC
EAC
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.65 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals is fashioned to match the requirements of industry specialists, such as switchboard fabricators, wiremen, maintenance companies, and Original Equipment manufacturers. GV4L07N6 yields first-rate reliability and beneficence for contractors in the power management industry. This Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are available the best price and supply period through BaltElec, a credible wholesaler supplying specialists in their purchasing needs.

Clients who have acquired Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have commonly applauded the producer's robustness. It has been pointed out that the excellent performance of GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals extends to a broad spectrum of scenarios. Its high-end properties make it right choice to cater to varied requirements, ensuring your industrial, tertiary and automation projects success.

Our team dedicates in accommodating industrial and tertiary professionals’ needs. We comprehend the special standards and expectations of our clients in the niche. By working with BaltElec, your team receive access to the superior pricing and delivery schedule of premium products like GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals from Schneider Electric at a competitive price. Registered customers take pleasure in more savings and dedicated support.

Start immediately and buy GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals at our certified and convenient virtual storefront. Don't delay in making this astute investment that promises the utmost quality and achieves the distinct needs of buyers like your outfit.

Should you have any uncertainties or concerns about GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals or any other Schneider Electric products, email us or refer to our Knowledge base section below. We have put together answers to usual questions to help you further in making an enlightened decision about industrial and tertiary electrical components.

Remember, GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals from Schneider Electric is sure, budget-friendly, and premier to alternative suppliers in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your infrastructure without delay. Purchase at BALTELEC, your reliable source for all your professional electrical equipment and automation needs.

In our Baltelec.eu web store you will encounter Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals - GV4L07N6 worth 267.21 €, which will be a reliable and modern solution for your wants. This goods is engineered by the Schneider Electric brand using the advanced technologies and fulfills the uppermost standards of security and capacity. We extend commodities from the TeSyS Deca GV4 Motor Circuit Breaker category that unite lastingness and effectiveness, which is an first-rate pick for various objectives. Notwithstanding of whether you demand hardware for small creation or for experienced industrial exertion, Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals will be a constant helper in your occupation.

Baltelec ventures to make the procuring process as comfortable and fast as feasible for our purchasers. We offer detailed depictions and high-quality images of Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals so that you can make an well-informed choice. A team of professionals is always ready to help you with any inquiries in the TeSyS Deca GV4 Motor Circuit Breaker section linked to the picking and use of materials. We are confident that Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals will meet your hopes and become an important element of your device for just 267.21 €.

Frequently Raised Questions about GV4L07N6 - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals:

Recently viewed
GV4L07N6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, lugs terminals
219,02 € excl. VAT
271,59 € incl. VAT
Expected in 2-4 weeks