SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 42…98 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 7 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
CCC
EAC
EU-RO MR
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.65 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4L07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals is crafted to fulfill the requirements of technical experts, such as electrical contractors, cable technicians, maintenance companies, and industry fabricators. GV4L07N delivers remarkable integrity and utility for developers in the energy management industry. This Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric are available at the most competitive price and delivery schedule through BALTELEC.EU, a dependable distributor helping professionals in their acquisition needs.

Technicians who have selected Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have commonly praised the creator's sturdiness. It has been mentioned that the excellent workmanship of GV4L07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals extends to a diverse range of implementations. Its elite features make it great selection to meet diverse demands, ensuring the success of your industrial, tertiary, and automation projects.

Our specialists centers in fulfilling industrial and tertiary professionals’ needs. We appreciate the customized specifications and requirements of our stakeholders in the niche. By aligning with us, your business get access to the superior rates and supply timeline of the top-of-the-line products like GV4L07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric at an attractive price. Registered customers appreciate additional savings and preferred assistance.

Act now and procure GV4L07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals at our well-established and efficient e-commerce site. Don't delay in making this prudent choice that affirms the best quality and achieves the particular standards of contractors like your outfit.

If you possess any matters or concerns about GV4L07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals or any other Schneider Electric products, get in touch with us or refer to our Assistance center section below. We have curated answers to typical inquiries to support you further in making an informed decision about industrial and tertiary electrical components.

Remember, GV4L07N - Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals from Schneider Electric is dependable, thrifty, and premier to its rivals in the TeSyS Deca GV4 Motor Circuit Breaker category. Feel free to make it a part of your configuration instantly. Acquire at BALTELEC, your preferred supplier for all your professional electrical equipment and automation needs.

In our Baltelec.eu e-commerce store you will find Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals - GV4L07N worth 283.24 €, which will be a dependable and fashionable solution for your preferences. This article is invented by the Schneider Electric brand using the state-of-the-art technologies and aligns with the peak standards of assurance and efficiency. We furnish articles from the TeSyS Deca GV4 Motor Circuit Breaker category that unite robustness and effectiveness, which is an superb choice for various functions. Without consideration of whether you need tools for small construction or for expert industrial application, Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals will be a secure partner in your assignment.

Baltelec strives to make the acquiring process as comfortable and fast as workable for our customers. We offer detailed accounts and high-quality images of Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals so that you can make an informed choice. A team of authorities is always ready to help you with any enquiries in the TeSyS Deca GV4 Motor Circuit Breaker section connected to the picking and use of supplies. We are assured that Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals will meet your needs and become an key element of your machinery for just 283.24 €.

Common Queries about GV4L07N:

Recently viewed
GV4L07N - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 7 A, Icu 50 kA, magnetic, EverLink terminals
232,16 € excl. VAT
287,88 € incl. VAT
Expected in 2-4 weeks