SPECIFICATIONS
Main
Device short name GV4L
Range TeSys Deca
TeSys Deca
magnetic tripping current 12…28 A
Product Name TeSys GV4
TeSys Deca
Trip unit technology Magnetic
Electronic
[ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
motor power kW 0.25 kW at 400...415 V AC 50/60 Hz
0.37 kW at 400...415 V AC 50/60 Hz
0.55 kW at 400...415 V AC 50/60 Hz
0.75 kW at 400...415 V AC 50/60 Hz
0.37 kW at 500 V AC 50/60 Hz
0.55 kW at 500 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 500 V AC 50/60 Hz
0.55 kW at 660...690 V AC 50/60 Hz
0.75 kW at 660...690 V AC 50/60 Hz
1.1 kW at 660...690 V AC 50/60 Hz
1.5 kW at 660...690 V AC 50/60 Hz
Complementary
[in] rated current 2 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC conforming to IEC 60947-2
[ith] conventional thermal current 115 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications IEC
CCC
EAC
EU-RO MR
Connection pitch 27 mm without spreaders
35 mm with spreaders
Handle front plate colour 155 mm
Product or component type Motor circuit breaker
tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Connections - terminals Lugs-ring terminals
Device application Motor protection
width (w) 81 mm
mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Colour Grey (RAL 7016)
Ik degree of protection IK07 conforming to IEC 62262
Net weight 1.65 kg
Operating position Any position
power dissipation per pole 6.1 W
depth 165 mm
mechanical durability 40000 cycles
electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Pollution degree 3
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -50…85 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP40 conforming to IEC 60529
operating altitude 5000 m
Range of product TeSys GV4
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-4-1
EN/IEC 60947-2
fire resistance 960 °C conforming to IEC 60695-2-11
About this product

The GV4L02N6 - Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals is produced to serve the demands of business buyers, such as panel manufacturers, circuit experts, maintenance companies, and equipment creators. GV4L02N6 provides first-rate excellence and advantages for professionals in the electrotechnical industry. This Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals and other TeSyS Deca GV4 Motor Circuit Breaker from Schneider Electric can be purchased the best price and shipping time through BaltElec online store, a respected vendor serving technicians in their supply needs.

Technicians who have selected Schneider Electric TeSyS Deca GV4 Motor Circuit Breaker have frequently appreciated the maker's reliability. It has been mentioned that the excellent capability of GV4L02N6 - Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals extends to a assortment of deployments. Its first-rate qualities make it perfect choice for multiple purposes, ensuring the success of your industrial, tertiary, and automation projects.

BaltElec specializes in providing for industrial and tertiary professionals’ needs. We recognize the individual standards and desires of our customers in the industry. By partnering with our professionals, your business secure access to the best charges and lead time of excellent products like GV4L02N6 - Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals from Schneider Electric at a competitive price. Registered users take pleasure in extra discounts and preferred assistance.

Begin today and get GV4L02N6 - Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals at our protected and convenient platform. Don't delay in making this shrewd selection that secures the best quality and achieves the individual expectations of purchasers like your enterprise.

Should there be any doubts or concerns about GV4L02N6 - Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals or any other Schneider Electric products, reach out to us or refer to our Knowledge base section below. We have amassed answers to standard problems to help you further in making an informed decision about industrial and tertiary electrical components.

Remember, GV4L02N6 - Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals from Schneider Electric is consistent, wallet-friendly, and high-quality to its competitors in the TeSyS Deca GV4 Motor Circuit Breaker category. Make it a part of your arrangement right now. Buy at baltele.eu, your preferred supplier for all your professional electrical equipment and automation needs.

In our Baltelec.eu internet store you will detect Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals - GV4L02N6 worth 267.21 €, which will be a trustworthy and cutting-edge solution for your expectations. This product is constructed by the Schneider Electric brand using the freshest technologies and fulfills the maximum standards of defense and competence. We extend items from the TeSyS Deca GV4 Motor Circuit Breaker category that fuse endurance and practicality, which is an premium choice for various tasks. Despite of whether you need instruments for small fabrication or for adept industrial implementation, Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals will be a dependable companion in your endeavor.

Baltelec aims to make the obtaining process as easy and fast as possible for our buyers. We offer detailed descriptions and high-quality shots of Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals so that you can make an knowledgeable choice. A team of experts is always ready to help you with any issues in the TeSyS Deca GV4 Motor Circuit Breaker section tied to the determining and use of articles. We are confident that Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals will meet your needs and become an important element of your hardware for just 267.21 €.

Frequently Raised Questions about Schneider Electric Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals:

Recently viewed
GV4L02N6 - Schneider Electric
Motor circuit breaker, TeSys GV4, 3P, 2 A, Icu 50 kA, magnetic, lugs terminals
219,02 € excl. VAT
271,59 € incl. VAT
Expected in 2-4 weeks