All categories
Compare Cart

GV3P186 - Motor circuit breaker, TeSys Deca, 3P, 1218 A, thermal magnetic, lugs terminals - Schneider Electric

Expected in 2-4 weeks
GV3P186 - Motor circuit breaker, TeSys Deca, 3P, 1218 A, thermal magnetic, lugs terminals - Schneider Electric - Motor circuit breaker, TeSys Deca, 3P, 1218 A, thermal magnetic, lugs terminals - Schneider Electric - 0
GV3P186 - Motor circuit breaker, TeSys Deca, 3P, 1218 A, thermal magnetic, lugs terminals - Schneider Electric
184,33 €
184,33 € incl. VAT
Text About:
Motor circuit breaker, TeSys Deca, 3P, 1218 A, thermal magnetic, lugs terminals - Schneider Electric
184,33 €
SPECIFICATIONS
Main
Device short name GV3P
Range TeSys Deca
magnetic tripping current 252 A
Product Name TeSys GV3
TeSys Deca
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
thermal protection adjustment range 12…18 A conforming to IEC 60947-4-1
motor power kW 7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 Hz
Complementary
[in] rated current 18 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 18 A conforming to IEC 60947-4-1
Control type Rotary handle
Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
Connection pitch 17.5 mm without spreaders
Handle front plate colour 132 mm
Product or component type Motor circuit breaker
tightening torque 6 N.m - on lugs-ring terminals
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Device application Motor protection
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
width (w) 55 mm
mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
network frequency 50/60 Hz conforming to IEC 60947-4-1
Colour Dark grey
Ik degree of protection IK09 enclosure
Net weight 0.96 kg
power dissipation per pole 8 W
depth 136 mm
mechanical durability 50000 cycles
electrical durability 50000 cycles for AC-3 at 415 V In
Network type AC
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1
Poles description 3P
Utilisation category AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -40…80 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP20 conforming to IEC 60529
operating altitude 3000 m
ambient air temperature for operation -20…60 °C
standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
fire resistance 960 °C conforming to IEC 60695-2-11
Recently viewed
184,33 €
184,33 € incl. VAT
Expected in 2-4 weeks