SPECIFICATIONS
Main
Device short name GV2RT
Range TeSys Deca
magnetic tripping current 78 A
Product Name TeSys GV2
TeSys Deca
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
thermal protection adjustment range 2.5…4 A conforming to IEC 60947-4-1
motor power kW 0.55 kW at 220/230 V AC 50/60 Hz motor protection high peak current
0.75 kW at 220/230 V AC 50/60 Hz motor protection high peak current
1.1 kW at 400/415 V AC 50/60 Hz motor protection high peak current
1.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current
1.5 kW at 440 V AC 50/60 Hz motor protection high peak current
1.5 kW at 500 V AC 50/60 Hz motor protection high peak current
2.2 kW at 500 V AC 50/60 Hz motor protection high peak current
2.2 kW at 690 V AC 50/60 Hz motor protection high peak current
3 kW at 690 V AC 50/60 Hz motor protection high peak current
1 kW at 230/240 V AC 50/60 Hz transformer protection
1.6 kW at 400/415 V AC 50/60 Hz transformer protection
2 kW at 400/415 V AC 50/60 Hz transformer protection
1.6 kW at 440 V AC 50/60 Hz transformer protection
2 kW at 440 V AC 50/60 Hz transformer protection
2 kW at 500 V AC 50/60 Hz transformer protection
2.5 kW at 500 V AC 50/60 Hz transformer protection
2.5 kW at 690 V AC 50/60 Hz transformer protection
Complementary
[in] rated current 4 A
[ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[ics] rated service breaking capacity 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[ith] conventional thermal current 4 A conforming to IEC 60947-4-1
Control type Toggle
Product certifications CCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
UKCA
Handle front plate colour 89 mm
Product or component type Motor circuit breaker
tightening torque 1.7 N.m - on screw clamp terminal
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Device application Motor protection
Motor
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
width (w) 45 mm
mechanical robustness Shocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5...150 Hz
network frequency 50/60 Hz conforming to IEC 60947-4-1
Ik degree of protection IK04
power dissipation per pole 2.5 W
depth 78.5 mm
mechanical durability 100000 cycles
electrical durability 100000 cycles for AC-3 at 415 V In
Network type AC
Rated duty Continuous conforming to IEC 60947-4-1
Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -40…80 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP20 conforming to IEC 60529
operating altitude 2000 m
ambient air temperature for operation -20…60 °C
standards EN/IEC 60947-2
EN/IEC 60947-4-1
fire resistance 960 °C conforming to IEC 60695-2-11