Main
Device short name
IHP
number of channels
2
Product Name
Acti9 IHP
Complementary
electrical insulation class
Class II
[ue] rated operational voltage
230 V AC +10 % -15 % at 50/60 Hz
absence for holidays
Yes
Accuracy
+/- 0.25 s/day 25 °C
maximum switching current
10 A - 250 V AC pf = 0.6
16 A - 250 V AC pf = 1
Handle front plate colour
92.6 mm
Product or component type
Programmable digital time switch
Cycle duration
24 hours + 7 days
Connections - terminals
2 x 0.5…2.5 mm² screw terminals solid or flexible
1 x 2.5 mm² screw terminals solid or flexible with sleeve
minimum interval duration
1 min
minimum switching current
10 mA 230 V AC
100 mA 24 V AC/DC
Contacts type
C/O
Language
English
Russian
Ukrainian
Latvian
Italian
Estonian
Bulgarian
Greek
Slovene
Serbian
Croatian
Hungarian
Polish
Romanian
Czech
Slovak
Turkish
Hebrew
marking
CE
Output type
Dry contact
Device application
Building
function
None
width (w)
45 mm
function available
Code lock function
Holiday schedules
Automatic winter/summer time changeover
On/off permanent switching
Manual operation
On/off switching times
Switch preselection
Net weight
130 g
Maximum number of switchings
56
updated by
None
Mounting support
TH35 DIN rail conforming to EN 60715
depth
66.7 mm
backup time
10 years time and program saving
Load type
incandescent lamp: 2600 W
halogen lamp: 2600 W
non-corrected fluorescent tube: 2600 VA
serial-compensated fluorescent tube: 2600 VA
parallel compensated fluorescent lamp: 400 VA (48 µF)
compact fluorescent lamp: 400 W
< 2 W LED lamp: 25 W
> 2 W LED lamp: 200 W
type of setting
Weekly programming
maximum power consumption in w
0.5 W standby
control button type
4 push-buttons
Time changeover
Automatic
Environment
Ambient air temp for storage/transportation
-30…70 °C
ip degree of protection
IP20
Range of product
Acti9
ambient air temperature for operation
-30…55 °C
overvoltage category
Class 3
standards
EN 60730-2-7:2010
relative humidity
90 %, non-condensing