SPECIFICATIONS
Main
Associated head ZCKD17
ZCKD59
ZCKD81
ZCKD219
ZCKD23
ZCKD02
ZCKD91
ZCKD10
ZCKD41
ZCKD239
ZCKD109
ZCKD08
ZCKD029
ZCKD06
ZCKD16
ZCKD21
ZCKD05
ZCKD15
Body type Fixed
Device short name ZCKL
[ithe] thermal current under enclosure 6 A
[ui] rated insulation voltage 400 V (pollution degree 3) conforming to IEC 60947-1 for contact block
300 V conforming to CSA C22.2 No 14 for contact block
300 V conforming to UL 508 for contact block
Series name Standard format
Complementary
product compatibility XCKL
[ie] rated operational current 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
local display Without
Handle front plate colour 64 mm
Product or component type Limit switch body
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry 1 tapped entry for Pg 13.5 cable gland (included)
Contacts material Silver plated contacts
contact operation Slow-break, break before make
Contacts type and composition 2 NC + 1 NO
body material Metal
width (w) 64 mm
Ik degree of protection IK05
Net weight 0.21 kg
depth 30 mm
electrical durability 5000000 cycles, DC-13 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Number of steps 1 1 position
Positive opening With
electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 0.75 mm²
Maximum resistance across terminals 0.25 mOhm conforming to IEC 60255-7 category 3
Minimum actuation speed 6 m/min
Poles description 3
Short-circuit protection 10 A cartridge fuse, type gG
Terminals description iso n°1 (21-22)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP66
Range of product Telemecanique Limit switches XC Standard
ambient air temperature for operation -25…70 °C for standard environment
Environmental characteristics Temperature variation
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

ZCKLD37 is a industrial Limit Switches XC solution designed for enterprises. BaltElec specializes in volume-based sales and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Authentic Telemecanique product, certificates and compliance documents available.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with trusted couriers.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a special offer. The price depends on quantity, delivery, and payment terms.

Limit Switches XC specifications may vary by configuration. For an exact match, please send us your requirements or check the technical data sheet.

FAQ for ZCKLD37 - Telemecanique

Recently viewed
ZCKLD37 - Telemecanique
Limit switch body, Limit switches XC Standard, ZCKL, 2NC+1 NO, slow break, Cable gland include
46,05 € excl. VAT
57,10 € incl. VAT
Pending restock