SPECIFICATIONS
Additional Information
type of order Toggle
type of pole 4P4D
Main
Number of modules 6
rated operational voltage ue 220 / 415 V
Complementary
air humidity protection for all climates
breaking capacity on 1 pole for it 230v nf 60947-2 21 kA
category of use A
complete device with protection unit Yes
connection cross-sect. flexible conductor 4 / 70mm²
correction factor of rating current for 2 devices placed side-by-side 1
din rail mounting with optional adaptator No
electric endurance in number of cycles 1000
magnetic trip delay time 0 ms
motor drive optional No
power loss per pole at in 11 W
range of the magnetic adjustment 1500 A
search words Compact circuit-breaker;Circuit-breaker;Main switch;Switch;Circuit-breaker;MCCB;
thermal protection trip time 0 ms
[in] rated current 125 A
breaking capacity on 1 pole for it 400v nf 60947-2 9 kA
connection cross-sect. rigid cable 4 / 95mm²
correction factor of rating current for 3 devices placed side-by-side 1
integrated earth fault protection No
number of mechanical operations 4000
setting type in or ith IN
time of response when opening 10 ms
total power loss under in 33 W
trip unit TM A/F
correction factor of rating current for 4 and 5 devices placed side-by-side 1
tripmode TM
type of connection with screw
with under voltage release No
correction factor of rating current for 6 devices placed side-by-side 1
rated service breaking capacity ics ac according iec 60947-2 80 %
storage/transport temperature -35…70 °C
rated ultimate short-circuit breaking capacity icu under 230v ac iec 60947-2 35 kA
Rated insulation voltage 690 V
rated ultimate short-circuit breaking capacity icu under 240v ac iec 60947-2 35 kA
connection Front connection
rated ultimate short-circuit breaking capacity icu under 400v ac iec 60947-2 25 kA
rated ultimate short-circuit breaking capacity icu under 415v ac iec 60947-2 25 kA
rated ultimate short-circuit breaking capacity icu under 440v ac iec 60947-2 20 kA
rated ultimate short-circuit breaking capacity icu under 690v ac iec 60947-2 4 kA
thermal protection nob setting xin 0.63 / 0.8 / 1
thermal setting current on neutral pole 1 In
frequency 50/60
rated impulse withstand voltage 8 kV
Poles description 4 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP4X
standard text IEC 60947-2
operating temperature -25…70 °C
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

HHA126H Hager is a industrial Circuit Brakers solution designed for companies. BaltElec specializes in volume-based sales and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Original Hager product, documentation available on request.
  • Volume-based pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a special offer. The price depends on quantity, delivery, and payment terms.

Circuit Brakers specifications may vary by configuration. For an exact match, please send us your application details or check the technical data sheet.

FAQ for HHA126H - Hager

Recently viewed
HHA126H - Hager
MCCB h3 x160 TM 4x125A 25kA
Pending restock