All categories
Compare Cart
LTMR27MFM - Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC - Schneider Electric - Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC - Schneider Electric - 0
LTMR27MFM - Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC - Schneider Electric - Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC - Schneider Electric - 0
Pending restock

LTMR27MFM – Schneider Electric

647,78 € excl. VAT
803,25 € incl. VAT
Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC - Schneider Electric
803,25 €
SPECIFICATIONS
Default
Series TeSyS LT
Main
Device short name LTMR
Measurement current 1.35…27 A
Range TeSys
Product Name TeSys T
[ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
Complementary
compatibility code LTMR
Product certifications RMRoS
LROS (Lloyds register of shipping)
RINA
ABS
CCC
EAC
UL
GL
NOM
DNV
KERI
ATEX
BV
CSA
C-Tick
Connection pitch 5.08 mm
Handle front plate colour 61 mm
Product or component type Motor controller
tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
[uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
[us] rated supply voltage 100...240 V AC 50/60 Hz
Current consumption 8...62.8 mA
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
current state 0 guaranteed Logic input: 0...40 V and <= 15 mA for 25 ms
Associated fuse rating 4 A gG for output
0.5 A gG for control circuit
Bus type Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, RJ45 with 2 shielded twisted pairs
Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs
current state 1 guaranteed Logic input: 79...264 V and >= 2 mA for 25 ms
Device application Equipment monitoring and control
Contacts type and composition 1 NO + 1 NC fault signal
3 NO
input current 3.1 mA at 100 V
7.5 mA at 240 V
Load current 5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
width (w) 91 mm
mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
supply voltage limits 93.5…264 V AC
Net weight 0.53 kg
measurement accuracy 5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
communication port protocol Modbus
depth 122.5 mm
Pollution degree 3
Maximum operating rate 1800 cyc/h
Logic input number 6
Maximum output switching frequency 2 Hz
Metering type Temperature
Phase current I1, I2, I3 RMS
Average current Iavg
Earth-fault current
Imbalance current
Network and machine diagnosis type Fault recording
Starting current and time
Remaining operating time before overload tripping
Waiting time after overload tripping
Motor control command recording
Event recording
Trip history information
Running hours counter/operating time
Phase fault and earth fault trip counters
Trip context information
Permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Protection type Reverse polarity protection
Overload (long time)
Earth-leakage protection
Phase unbalance
Overload
Load fluctuation
Phase failure
Power factor variation
Thermal protection
Locked rotor
Thermal overload protection
Web services Web server
Environment
Ambient air temp for storage/transportation -40…80 °C
ip degree of protection IP20
operating altitude <= 2000 m without derating
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
overvoltage category III
standards CSA C22.2 No 14
UL 508
EN 60947-4-1
IEC 60947-4-1
IACS E10
fire resistance 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

LTMR27MFM is a industrial TeSyS LT product designed for professionals. BaltElec specializes in wholesale and supply in Estonia, Latvia, Lithuania, and Finland.

  • Original Schneider Electric product, documentation available on request.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a project quote. The price depends on quantity, delivery, and payment terms.

TeSyS LT specifications may vary by configuration. For an exact match, please send us your application details or check the technical data sheet.

FAQ for LTMR27MFM - Schneider Electric

Recently viewed
LTMR27MFM - Schneider Electric
Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC
647,78 € excl. VAT
803,25 € incl. VAT
Pending restock