All categories
Compare Cart
LC2D80ABBE - TeSys Deca reversing contactor 3P 66A AC3/AC3e up to 440V coil 24V DC - Schneider Electric - TeSys Deca reversing contactor 3P 66A AC3/AC3e up to 440V coil 24V DC - Schneider Electric - 0
LC2D80ABBE - TeSys Deca reversing contactor 3P 66A AC3/AC3e up to 440V coil 24V DC - Schneider Electric - TeSys Deca reversing contactor 3P 66A AC3/AC3e up to 440V coil 24V DC - Schneider Electric - 0
Pending restock

LC2D80ABBE – Schneider Electric

664,61 € excl. VAT
824,12 € incl. VAT
TeSys Deca reversing contactor 3P 66A AC3/AC3e up to 440V coil 24V DC - Schneider Electric
824,12 €
SPECIFICATIONS
Default
Series TeSyS Deca Contactors
Main
Contactor application Resistive load
Motor control
Device short name LC2D
Interlocking type Mechanical
Range TeSys
TeSys Deca
[uc] control circuit voltage 24 V DC
Front cover With
Product Name Tesys Deca green
TeSys Deca
Motor power hp (ul / csa) 5 hp at 115 V AC 60 Hz for 1 phase motors
10 hp at 230/240 V AC 60 Hz for 1 phase motors
20 hp at 200/208 V AC 60 Hz for 3 phases motors
20 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
50 hp at 575/600 V AC 60 Hz for 3 phases motors
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
control circuit type DC low consumption
motor power kW 18.5 kW at 220...230 V AC 50 Hz
37 kW at 380...400 V AC 50 Hz
37 kW at 415 V AC 50 Hz
37 kW at 440 V AC 50 Hz
37 kW at 500 V AC 50 Hz
37 kW at 660...690 V AC 50 Hz
average impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
Complementary
[ie] rated operational current 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
66 A (at <60 °C) at <= 440 V AC-3 for power circuit
66 A (at <60 °C) AC-3e for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 25...400 Hz
[ics] rated service breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
520 A 40 °C - 10 s for power circuit
900 A 40 °C - 1 s for power circuit
110 A 40 °C - 10 min for power circuit
260 A 40 °C - 1 min for power circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuit
Product certifications CCC
CSA
EAC
UL
KC
DNV-GL
LROS (Lloyds register of shipping)
UKCA
Handle front plate colour 122 mm
Product or component type Reversing contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Control circuit voltage limits <= 0.1 Uc (-40…70 °C):drop-out DC
0.8...1.2 Uc (-40…60 °C):operational DC
1...1.2 Uc (60…70 °C):operational DC
width (w) 119 mm
mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor open: 10 Gn for 11 ms
Shocks contactor closed: 15 Gn for 11 ms
Colour Grey (SE GREY 6)
Green (SE GREEN 2)
Flame retardance V1 conforming to UL 94
Heat dissipation 0.5 W
Net weight 2.174 kg
Hold-in power consumption in w 0.5 W at 20 °C
Mounting support Rail
Plate
power dissipation per pole 9.6 W AC-1
6.5 W AC-3
6.5 W AC-3e
depth 120 mm
inrush power in w 11 W at 20 °C
mechanical durability 6 Mcycles
electrical durability 1 Mcycles 66 A AC-3 at Ue <= 440 V
0.5 Mcycles 80 A AC-1 at Ue <= 440 V
1 Mcycles 66 A AC-3e
Device presentation Preassembled with reversing power busbar
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 55...65 ms closing
20...80 ms opening
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
coil technology Built-in bidirectional peak limiting
Poles description 3P
Utilisation category AC-1
AC-3
AC-3e
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Ambient air temp for storage/transportation -60…80 °C
Climatic withstand conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
ambient air temperature for operation -40…60 °C
60…70 °C with derating
overvoltage category III
standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

LC2D80ABBE Schneider Electric is a industrial TeSyS Deca Contactors product designed for professionals. BaltElec specializes in volume-based sales and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Authentic Schneider Electric product, documentation available on request.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Fast delivery across the Baltics and Finland; cooperation with trusted couriers.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a special offer. The price depends on quantity, delivery, and payment terms.

TeSyS Deca Contactors specifications may vary by model. For an exact match, please send us your requirements or check the technical data sheet.

FAQ for LC2D80ABBE - Schneider Electric

Recently viewed
LC2D80ABBE - Schneider Electric
TeSys Deca reversing contactor 3P 66A AC3/AC3e up to 440V coil 24V DC
664,61 € excl. VAT
824,12 € incl. VAT
Pending restock