All categories
Compare Cart
LC1D258MD - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 40 A 220 V DC coil - Schneider Electric - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 40 A 220 V DC coil - Schneider Electric - 0
LC1D258MD - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 40 A 220 V DC coil - Schneider Electric - TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 40 A 220 V DC coil - Schneider Electric - 0
Pending restock

LC1D258MD – Schneider Electric

82,03 € excl. VAT
101,72 € incl. VAT
TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 40 A 220 V DC coil - Schneider Electric
101,72 €
SPECIFICATIONS
Default
Series TeSyS Deca Contactors
Main
Contactor application Resistive load
Device short name LC1D
[uc] control circuit voltage 220 V DC
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
control circuit type DC standard
average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
Complementary
[ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
compatibility code LC1D
[ics] rated service breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 240 A 40 °C - 10 s for power circuit
380 A 40 °C - 1 s for power circuit
50 A 40 °C - 10 min for power circuit
120 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[ith] conventional thermal current 10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
Product certifications UL
CSA
CCC
EAC
UKCA
CB
EU-RO-MR by DNV-GL
Handle front plate colour 91 mm
Product or component type Contactor
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.8 N.m - on screw clamps terminals - with screwdriver Philips No 2
Power circuit: 1.8 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
minimum switching current 5 mA for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
contact compatibility M7
Control circuit voltage limits 0.1...0.25 Uc (-40…60 °C):drop-out DC
0.7...1.25 Uc (-40…60 °C):operational DC
width (w) 45 mm
mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
Net weight 0.585 kg
time constant 28 ms
Hold-in power consumption in w 5.4 W at 20 °C
Mounting support Plate
Rail
power dissipation per pole 3.2 W AC-1
depth 107 mm
inrush power in w 5.4 W (at 20 °C)
mechanical durability 30 Mcycles
electrical durability 1.4 Mcycles 40 A AC-1 at Ue <= 440 V
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
Pollution degree 3
Maximum operating rate 3600 cyc/h 60 °C
operating time 53.55...72.45 ms closing
16...24 ms opening
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Protective cover With
coil technology Built-in bidirectional peak limiting diode suppressor
Pole contact composition 2 NO + 2 NC
Poles description 4P
Utilisation category AC-1
AC-3
AC-3e
AC-4
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency 25...400 Hz
Environment
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Range of product TeSys Deca
overvoltage category III
standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
fire resistance 850 °C conforming to IEC 60695-2-1
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MOhm for signalling circuit
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

Schneider Electric LC1D258MD is a professional TeSyS Deca Contactors product designed for professionals. BaltElec specializes in volume-based sales and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Original Schneider Electric product, documentation available on request.
  • Volume-based pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with trusted couriers.
  • Technical support and application suitability advice based on your requirements.

Pricing: Request a special offer. The price depends on quantity, delivery, and payment terms.

TeSyS Deca Contactors specifications may vary by model. For an exact match, please send us your application details or check the technical data sheet.

FAQ for LC1D258MD - Schneider Electric

Recently viewed
LC1D258MD - Schneider Electric
TeSys Deca contactor 4P(2 NO + 2 NC) AC1 <= 440 V 40 A 220 V DC coil
82,03 € excl. VAT
101,72 € incl. VAT
Pending restock