All categories
Compare Cart
50490 - Insulation monitoring XML308 Vigilohm 115..127 V AC 50/60 Hz failsafe - Schneider Electric - Insulation monitoring XML308 Vigilohm 115..127 V AC 50/60 Hz failsafe - Schneider Electric - 0
50490 - Insulation monitoring XML308 Vigilohm 115..127 V AC 50/60 Hz failsafe - Schneider Electric - Insulation monitoring XML308 Vigilohm 115..127 V AC 50/60 Hz failsafe - Schneider Electric - 0
Upon request only

50490 – Schneider Electric

Insulation monitoring XML308 Vigilohm 115..127 V AC 50/60 Hz failsafe - Schneider Electric
SPECIFICATIONS
Default
Series VigilOhm
Main
Device short name XML308
Measurement current 0…5 mA
scale 0.1...999 kOhm
Fail safe feature With
number of channels 8
Measurement voltage 6 V
Earthing system IT
Complementary
[ue] rated operational voltage <= 1000 V AC 45...400 Hz device connected to phase with PHT1000 subassembly
<= 1200 V DC device connected with PHT1000
<= 1700 V AC 45...400 Hz device connected to neutral with PHT1000 subassembly
<= 440 V AC 45...400 Hz device connected to phase
<= 500 V DC
<= 760 V AC 45...400 Hz device connected to neutral
auxiliary connection terminal Tunnel type terminalsflexible 0.75…1.5 mm²
Tunnel type terminalsrigid 1…1.5 mm²
[ics] rated service breaking capacity 10 A at 24 V DC, L/R = 1 ms
0.45 A at 220 V DC, L/R = 1 ms
0.65 A at 120 V DC, L/R = 1 ms
2.5 A at 48 V DC, L/R = 1 ms
5 A at 230 V AC, cos phi = 0.7
3 A at 400 V AC, cos phi = 0.7
Handle front plate colour 129 mm
[us] rated supply voltage 115...127 V AC 50/60 Hz tolerance: - 15...10 %
type of measurement Network insulation resistance, earth leakage capacitance, local measurement
width (w) 229 mm
Mounting mode Flush-mounted
Net weight 4.5 kg
Display type LCD
Mounting support Enclosure
Plate
Cubicle
depth 213.5 mm
Polling time 15 s
Power consumption in va 30 VA
mounting position Horizontal mounting
Tamperproof of settings Protected by access code
Protected by sealable cover
Signal contacts composition 3 C/O
Test function Manual, self test
dielectric strength 2500 V
Signalling function Alarm
Device fault
Insulation value display
Transient fault
Environment
Ambient air temp for storage/transportation -20…70 °C
ip degree of protection IP30
Range of product Vigilohm
ambient air temperature for operation -5…55 °C
standards NF C 15-100 §413.4
IEC 364 ch 4 and 5
UTE C 63-080 classes CPI/XA, DLD/M
IEC 61557-8
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

50490 is a industrial VigilOhm solution designed for professionals. BaltElec specializes in wholesale and supply in Estonia, Latvia, Lithuania, and Finland.

  • Authentic Schneider Electric product, certificates and compliance documents available.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and application suitability advice based on your requirements.

Pricing: Request a project quote. The price depends on quantity, delivery, and payment terms.

VigilOhm specifications may vary by model. For an exact match, please send us your application details or check the technical data sheet.

FAQ for 50490 - Schneider Electric

Recently viewed
50490 - Schneider Electric
Insulation monitoring XML308 Vigilohm 115..127 V AC 50/60 Hz failsafe
Upon request only