SPECIFICATIONS
Additional Information
- at bridging between non-adjacent terminal blocks 352 V
bridge data 24 A / 4 mm²
connection capacity awg 28 ... 12
- at cut-to-length bridging 220 V
connection capacity flexible 0.08 mm² ... 4 mm²
connection capacity rigid 0.08 mm² ... 6 mm²
identification  II 2 GD  Ex eb IIC Gb
ex temperature increase 40 K (29.5 A / 4 mm²)
output (Permanent)
for bridging with bridge 440 V
rated cross section awg 12
Main
calorimetric heat release nfpa 130 (astm e 1354) 27,5 MJ/kg
catalog page Page 230 (C-1-2019)
flammability rating according to ul 94 V0
insulating material PA
fire protection for rail vehicles (din en 45545-2) r22 HL 1 - HL 3
relative insulation material temperature index (elec., ul 746 b) 130 °C
fire protection for rail vehicles (din en 45545-2) r23 HL 1 - HL 3
gtin 4017918186920
number of rows 2
Product type Multi-level terminal block
fire protection for rail vehicles (din en 45545-2) r24 HL 1 - HL 3
item number 3031429
potentials 2
Rated voltage 440 V
fire protection for rail vehicles (din en 45545-2) r26 HL 1 - HL 3
nominal cross section 4 mm²
packing unit 50 pc
product key BE2114
insulating material group I
weight per piece (excluding packing) 15.434 g
weight per piece (including packing) 16.375 g
smoke gas toxicity nfpa 130 (smp 800c) passed
specific optical density of smoke nfpa 130 (astm e 662) passed
static insulating material application in cold -60 °C
surface flammability nfpa 130 (astm e 162) passed
temperature index of insulation material (din en 60216-1 (vde 0304-21)) 125 °C
Complementary
end cover width 2.2 mm
maximum power dissipation for nominal condition 1.02 W
open side panel Yes
[in] rated current 26.5 A
height ns 35/7,5 47.5 mm
number of connections 4
rated surge voltage 6 kV
conductor cross section, flexible [awg] 28 ... 12 (converted acc. to IEC)
Country of origin DE
height ns 35/15 55 mm
length [l] 83.5 mm
2 conductors with the same cross section, flexible, with twin ferrule with plastic sleeve 0.5 mm² ... 1 mm²
conductor cross section, rigid [awg] 0.08 mm² ... 6 mm²
Handle front plate colour 1.87 "
connection in acc. with standard IEC 60947-7-1
cross section awg 28 ... 10 (converted acc. to IEC)
Rated insulation voltage 400 V
conductor cross section flexible, with ferrule without plastic sleeve 0.14 mm² ... 4 mm²
flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 4 mm²
nominal voltage 500 V
internal cylindrical gage A4
number of connections per level 2
width (w) 6.2 mm
Colour gray
stripping length 8 mm ... 10 mm
Minimum order quantity 1 pc
nominal current 30 A (with 4 mm² conductor cross section)
contact resistance 0.69 mΩ
frequency f1 = 5 Hz to f2 = 250 Hz
Maximum load current 30 A
Environment
acceleration 30g
Ambient air temp for storage/transportation -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient air temperature for installation -5 °C ... 70 °C
ambient temperature (actuation) -5 °C ... 70 °C
china rohs Environmentally friendly use period: unlimited = EFUP-e
Customs tariff number 85369010
degree of pollution 3
din rail/fixing support NS 35
eclass-11.0 27141120
requirement temperature-rise test Increase in temperature ≤ 45 K
Specifications - Environmental Product Compliance: No hazardous substances above threshold values
ambient air temperature for operation -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
ETIM - 8 EC000897
overvoltage category III
result Test passed
revolutions 135
operating temperature range -60 °C ... 110 °C
rotation speed 10 rpm
short-time withstand current 4 mm² 0.48 kA
short-time withstand current 6 mm² 0.72 kA
test force setpoint 1 N
test voltage setpoint 1.89 kV
permissible humidity (storage/transport) 30 % ... 70 %
unspsc 21.0 39121400
asd level 6.12 (m/s²)²/Hz
time of exposure 30 s
number of shocks per direction 3
pulse shape Half-sine
shock duration 18 ms
specification DIN EN 50155 (VDE 0115-200):2008-03
spectrum Service life test category 2, bogie-mounted
temperature cycles 192
test directions X-, Y- and Z-axis (pos. and neg.)
test duration per axis 5 h
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

3031429 is a professional Terminal Blocks, Cable Ends product designed for enterprises. BaltElec specializes in wholesale and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Authentic Phoenix Contact product, certificates and compliance documents available.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a project quote. The price depends on quantity, delivery, and payment terms.

Terminal Blocks, Cable Ends specifications may vary by model. For an exact match, please send us your application details or check the technical data sheet.

FAQ for 3031429 - Phoenix Contact

Recently viewed
Pending restock