All categories
Compare Cart

CA2SKE20Q7 - TeSys SK control relay 2 NO <= 690 V 380 V AC coil - Schneider Electric

Expected in 2-4 weeks
CA2SKE20Q7 - TeSys SK control relay 2 NO <= 690 V 380 V AC coil - Schneider Electric - TeSys SK control relay 2 NO <= 690 V 380 V AC coil - Schneider Electric - 0
CA2SKE20Q7 - TeSys SK control relay 2 NO <= 690 V 380 V AC coil - Schneider Electric
61,89 € excl. VAT
75,50 € incl. VAT
Text About:
TeSys SK control relay 2 NO <= 690 V 380 V AC coil - Schneider Electric
75,50 €
SPECIFICATIONS
Main
Contactor application Control circuit
Device short name CA2SKE
Range TeSys
[uc] control circuit voltage 380 V AC 50/60 Hz
Product Name TeSys CASK
[ui] rated insulation voltage 690 V conforming to IEC 60947
690 V conforming to VDE 0110 group C
690 V conforming to BS 5424
690 V conforming to UL 508
690 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
Complementary
[ue] rated operational voltage <= 690 V <= 400 Hz
[ith] conventional thermal current 10 A (at 55 °C)
Product certifications CB Scheme
cULus
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Control relay
tightening torque 0.8 N.m - on screw clamp terminals pozidriv No 1 screw head
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…6 mm²solid
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.5…6 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.35…6 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.35…1.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.35…2.5 mm²flexible without cable end
Associated fuse rating 10 A gL conforming to VDE 0660
10 A gL conforming to IEC 60947
Control circuit voltage limits Drop-out: 0.2...0.75 Uc (at <50 °C)
Operational: 0.85...1.1 Uc (at <50 °C)
width (w) 45 mm
Heat dissipation 1.5 W
Net weight 0.132 kg
Hold-in power consumption in va 4.9 VA (at 20 °C)
Mounting support Plate
Rail
depth 68 mm
Inrush power in va 23 VA (at 20 °C)
mechanical durability 10 Mcycles
Maximum operating rate 1200 cyc/h
operating time 6...8 ms coil de-energisation and NO opening
7...14 ms coil energisation and NO closing
Pole contact composition 2 NO
Utilisation category DC-13
AC-15
Environment
Ambient air temp for storage/transportation -50…70 °C
ip degree of protection IP2X
operating altitude 2000 m without derating
ambient air temperature for operation -20…50 °C
standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
protective treatment TC conforming to IEC 60068
Recently viewed
61,89 € excl. VAT
75,50 € incl. VAT
Expected in 2-4 weeks