SPECIFICATIONS
Main
Contactor application Control circuit
Device short name CA2K
Range TeSys
[uc] control circuit voltage 380...400 V AC 50/60 Hz
Product Name TeSys CAK
[ui] rated insulation voltage 690 V conforming to IEC 60947
750 V conforming to VDE 0110 group C
690 V conforming to BS 5424
600 V conforming to CSA C22.2 No 14
control circuit type AC at 50/60 Hz
Complementary
[ue] rated operational voltage <= 690 V <= 400 Hz
[ith] conventional thermal current 10 A (at 50 °C)
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Control relay
tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 26 mm
1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible without cable end
minimum switching current 5 mA
Associated fuse rating 10 A gG conforming to IEC 60947
10 A gG conforming to VDE 0660
Control circuit voltage limits Drop-out: 0.2...0.75 Uc (at <50 °C)
Operational: 0.8...1.15 Uc (at <50 °C)
width (w) 45 mm
mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.18 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Immunity to microbreaks 2 ms
Mounting support Rail
Plate
depth 57 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 10 Mcycles
Irms rated making capacity 110 A conforming to IEC 60947
Maximum operating rate 10000 cyc/h
operating time 10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
15...25 ms coil de-energisation and NC closing
5...15 ms coil energisation and NC opening
minimum switching voltage 17 V
Non overlap distance 0.5 mm
Pole contact composition 2 NO + 2 NC
Utilisation category DC-13
AC-15
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP2X
operating altitude 2000 m without derating
ambient air temperature for operation -25…50 °C
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
insulation resistance > 10 MOhm