All categories
Compare Cart

C63W31M500 - Circuit breaker, ComPacT NSX630HB2, 100kA/690VAC, 3 poles, MicroLogic 1.3M trip unit 500A - Schneider Electric

Expected in 2-4 weeks EAN: 3606481989246
C63W31M500 - Circuit breaker, ComPacT NSX630HB2, 100kA/690VAC, 3 poles, MicroLogic 1.3M trip unit 500A - Schneider Electric - Circuit breaker, ComPacT NSX630HB2, 100kA/690VAC, 3 poles, MicroLogic 1.3M trip unit 500A - Schneider Electric - 0
EAN: 3606481989246
C63W31M500 - Circuit breaker, ComPacT NSX630HB2, 100kA/690VAC, 3 poles, MicroLogic 1.3M trip unit 500A - Schneider Electric
2 011,91 €
2 011,91 € incl. VAT
Text About:
Circuit breaker, ComPacT NSX630HB2, 100kA/690VAC, 3 poles, MicroLogic 1.3M trip unit 500A - Schneider Electric
2 011,91 €
SPECIFICATIONS
Main
Range ComPacT nouvelle génération
sectioning ability Oui se conformer à EN/CEI 60947-2
job category Catégorie A
name of the device NSX630HB2
type of product or equipment Disjoncteur
Product Name ComPacT NSX nouvelle génération
[ui] rated insulation voltage 800 V CA 50/60 Hz
trigger protection functions SI
circuit breaker installation mode Fixe
performance level HB2 100 kA 690 V CA
trigger name Micrologic 1.3 M
type of trigger Électronique
ultimate short-circuit breaking capacity [icu] 100 kA Icu à 500 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA Icu à 525 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA Icu à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
protected poles 3d
Complementary
"no" connection 45 mm
[in] rated operational current 500 A à 65 °C
[ue] rated operational voltage 690 V CA 50/60 Hz
application Protection moteur
[ics] rated service breaking capacity 100 kA à 500 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA à 525 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
short-time protection threshold setting range [isd] 2500 A
3000 A
3500 A
4000 A
4500 A
5000 A
5500 A
6000 A
6500 A
Handle front plate colour 255 mm
trigger caliber 500 A à 65 °C
[uimp] rated impulse withstand voltage 8 kV
product weight 6,2 kg
tsd short time protection time delay setting Fixe
electrical life 8000 cycle à 440 V In/2
4000 cycle à 440 V In
6000 cycle à 690 V In/2
2000 cycle à 690 V In
setting the differential protection time delay δt Réglable 9 positions
mechanical endurance 15000 cycle
width (w) 140 mm
network frequency 50/60 Hz
Local signalling pourprêt à fonctionner DEL clignotante (vert)
upstream connection Façade
downstream connection Façade
instantaneous protection threshold setting range [ii] (short-circuit protection) 6500 A
number of slots for electrical auxiliaries 6 slot(s)
mounting bracket Plaque arrière
depth (p) 110 mm
Network type CA
differential protection Sans
mounting position Horizontal et vertical
Flat on the back
power loss per pole 25 W
instantaneous protection sensor setting ii (short circuit protection) Fixe
order type Par maneton
kind of protection S : for protection court retard
I : for protection instantanée contre court-circuit
zsi logic selective latch area Sans
Poles description 3P
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 se conformer à CEI 60529
operating altitude 0...2000 m sans réduction de courant
2000 m...5000 m avec réduction de courant
product certificates CCC
EAC
Marine
class of protection against electric shock Classe II
overvoltage category Classe II
standards EN/CEI 60947
relative humidity 0…95 %
shock resistance ik IK07 se conformer à CEI 62262
operating ambient air temperature -25…70 °C
storage room temperature -50…85 °C
Recently viewed
2 011,91 €
2 011,91 € incl. VAT
Expected in 2-4 weeks