All categories
Compare Cart

C40K42D250 - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 4 - Schneider Electric

Expected in 2-4 weeks
C40K42D250 - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 4 - Schneider Electric - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 4 - Schneider Electric - 0
C40K42D250 - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 4 - Schneider Electric
2 344,00 €
2 344,00 € incl. VAT
Text About:
Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 4 - Schneider Electric
2 344,00 €
SPECIFICATIONS
Main
Device short name ComPacT NSX400K
Range ComPacT
circuit breaker mounting mode Fixed
Neutral position Left
Protected poles description 3t
3t + N/2
4t
Trip unit name Micrologic 2.3
Trip unit technology Electronic
Trip unit rating 250 A at 40 °C
[ui] rated insulation voltage 1000 V AC 50/60 Hz
Trip unit protection functions LSoI
performance level K 10 kA 1000 V AC
Complementary
[ii] instantaneous pick-up adjustment range 3000 A
[in] rated current 250 A at 40 °C
[ue] rated operational voltage 800...1000 V AC 50/60 Hz
[ics] rated service breaking capacity 10 kA at 800 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 1000 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
depth (d) 110 mm
Product certifications CE
CCC
[ir] long-time protection pick-up adjustment range 70...250 A
Connection pitch 45 mm
Handle front plate colour 255 mm
Product or component type Circuit breaker
[isd] short-time protection pick-up adjustment range 1.5...10 x Ir
[uimp] rated impulse withstand voltage 8 kV
[tr] long-time delay adjustment range 11 s at 7.2 x Ir
16 s at 6 x Ir
400 s at 1.5 x Ir
Device application Special application
Electrical shock protection class Class II
width (w) 185 mm
network frequency 50/60 Hz
thermal memory 20 minutes before and after tripping
Ik degree of protection IK07 conforming to IEC 62262
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
long-time pick-up adjustment type ir (thermal protection) Adjustable 9 settings
Net weight 7.9 kg
long-time protection delay adjustment type tr Fixed
Downside connection Front
number of slots for electrical auxiliaries 6 slot(s)
Earth-leakage protection Without
Mounting support Backplate
mechanical durability 15000 cycles
neutral protection setting 0.5 x Ir (3t + N/2)
1 x Ir (4t)
No protection (3t)
electrical durability 1000 cycles at 1000 V In
Network type AC
instantaneous protection pick-up adjustment type ii Fixed
Pollution degree 3 conforming to IEC 60664-1
short-time protection delay adjustment type tsd Fixed
short-time protection pick-up adjustment type isd Adjustable 9 settings
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 4P
Upside connection Front
Utilisation category Category A
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Zone selective interlocking zsi Without
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
operating altitude 0...2000 m without derating
2000 m...5000 m with derating
Range of product ComPact NSX400...630
ambient air temperature for operation -25…70 °C
overvoltage category IV
standards EN/IEC 60947
relative humidity 0…95 %
Recently viewed
2 344,00 €
2 344,00 € incl. VAT
Expected in 2-4 weeks