All categories
Compare Cart

C40K32D250 - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 3 - Schneider Electric

Expected in 2-4 weeks
C40K32D250 - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 3 - Schneider Electric - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 3 - Schneider Electric - 0
C40K32D250 - Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 3 - Schneider Electric
1 897,83 €
1 897,83 € incl. VAT
Text About:
Circuit breaker ComPacT NSX400K, 36kA at 800VAC, 10kA at 1000VAC, MicroLogic 2.3 trip unit, 250A, 3 - Schneider Electric
1 897,83 €
SPECIFICATIONS
Main
Device short name ComPacT NSX400K
Range ComPacT
circuit breaker mounting mode Fixed
Protected poles description 3t
Trip unit name Micrologic 2.3
Trip unit technology Electronic
Trip unit rating 250 A at 40 °C
[ui] rated insulation voltage 1000 V AC 50/60 Hz
Trip unit protection functions LSoI
performance level K 10 kA 1000 V AC
Complementary
[ii] instantaneous pick-up adjustment range 3000 A
[in] rated current 250 A at 40 °C
[ue] rated operational voltage 800...1000 V AC 50/60 Hz
[ics] rated service breaking capacity 10 kA at 800 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 1000 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
depth (d) 110 mm
Product certifications CE
CCC
[ir] long-time protection pick-up adjustment range 70...250 A
Connection pitch 45 mm
Handle front plate colour 255 mm
Product or component type Circuit breaker
[isd] short-time protection pick-up adjustment range 1.5...10 x Ir
[uimp] rated impulse withstand voltage 8 kV
[tr] long-time delay adjustment range 11 s at 7.2 x Ir
16 s at 6 x Ir
400 s at 1.5 x Ir
Device application Special application
Electrical shock protection class Class II
width (w) 140 mm
network frequency 50/60 Hz
thermal memory 20 minutes before and after tripping
Ik degree of protection IK07 conforming to IEC 62262
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
long-time pick-up adjustment type ir (thermal protection) Adjustable 9 settings
Net weight 6.05 kg
long-time protection delay adjustment type tr Fixed
Downside connection Front
number of slots for electrical auxiliaries 6 slot(s)
Earth-leakage protection Without
Mounting support Backplate
mechanical durability 15000 cycles
electrical durability 1000 cycles at 1000 V In
Network type AC
instantaneous protection pick-up adjustment type ii Fixed
Pollution degree 3 conforming to IEC 60664-1
short-time protection delay adjustment type tsd Fixed
short-time protection pick-up adjustment type isd Adjustable 9 settings
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 3P
Upside connection Front
Utilisation category Category A
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Zone selective interlocking zsi Without
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
operating altitude 0...2000 m without derating
2000 m...5000 m with derating
Range of product ComPact NSX400...630
ambient air temperature for operation -25…70 °C
overvoltage category IV
standards EN/IEC 60947
relative humidity 0…95 %
Recently viewed
1 897,83 €
1 897,83 € incl. VAT
Expected in 2-4 weeks