SPECIFICATIONS
Main
Range ComPacT nouvelle génération
sectioning ability Oui se conformer à EN/CEI 60947-2
job category Catégorie A
name of the device NSX250HB2
type of product or equipment Disjoncteur
Product Name ComPacT NSX nouvelle génération
[ui] rated insulation voltage 800 V CA 50/60 Hz
trigger protection functions I
circuit breaker installation mode Fixe
performance level HB2 100 kA 690 V CA
trigger name MA
type of trigger Magnétique
ultimate short-circuit breaking capacity [icu] 100 kA Icu à 500 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA Icu à 525 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA Icu à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
protected poles 3d
Complementary
"no" connection 35 mm
[in] rated operational current 150 A à 65 °C
[ue] rated operational voltage 690 V CA 50/60 Hz
application Protection moteur
[ics] rated service breaking capacity 100 kA à 500 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA à 525 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
short-time protection threshold setting range [isd] 9...14 x In
Handle front plate colour 161 mm
trigger caliber 150 A à 65 °C
[uimp] rated impulse withstand voltage 8 kV
product weight 2,4 kg
electrical life 20000 cycle à 440 V In/2
10000 cycle à 440 V In
10000 cycle à 690 V In/2
5000 cycle à 690 V In
setting the differential protection time delay δt Réglable
mechanical endurance 20000 cycle
width (w) 105 mm
network frequency 50/60 Hz
upstream connection Façade
downstream connection Façade
instantaneous protection threshold setting range [ii] (short-circuit protection) 9...14 x In
number of slots for electrical auxiliaries 5 slot(s)
mounting bracket Plaque arrière
depth (p) 86 mm
Network type CA
differential protection Sans
mounting position Horizontal et vertical
Flat on the back
power loss per pole 8,55 W
instantaneous protection sensor setting ii (short circuit protection) Réglable 9 positions
order type Par maneton
kind of protection I : for protection (magnétique) court-circuit
Poles description 3P
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 se conformer à CEI 60529
operating altitude 0...2000 m sans réduction de courant
2000 m...5000 m avec réduction de courant
product certificates CCC
Marine
EAC
class of protection against electric shock Classe II
operating ambient temperature -25…70 °C
overvoltage category Classe II
standards EN/CEI 60947
relative humidity 0…95 %
shock resistance ik IK07 se conformer à CEI 62262
storage room temperature -50…85 °C