All categories
Compare Cart

C2544V250 - Trip unit MicroLogic Vigi 4.2, ComPacT NSX250, 4 poles, electronic basic and earth leakage protections, 250A rating - Schneider Electric

5 In stock EAN: 3606481993878
C2544V250 - Trip unit MicroLogic Vigi 4.2, ComPacT NSX250, 4 poles, electronic basic and earth leakage protections, 250A rating - Schneider Electric - Trip unit MicroLogic Vigi 4.2, ComPacT NSX250, 4 poles, electronic basic and earth leakage protections, 250A rating - Schneider Electric - 0
EAN: 3606481993878
C2544V250 - Trip unit MicroLogic Vigi 4.2, ComPacT NSX250, 4 poles, electronic basic and earth leakage protections, 250A rating - Schneider Electric
728,02 € excl. VAT
888,18 € incl. VAT
Text About:
Trip unit MicroLogic Vigi 4.2, ComPacT NSX250, 4 poles, electronic basic and earth leakage protections, 250A rating - Schneider Electric
888,18 €
SPECIFICATIONS
Main
product range ComPacT NSX100...250 nouvelle génération
Range ComPacT nouvelle génération
type of product or equipment Déclencheur
trigger protection functions LSoIR
circuit breaker installation mode Fixe
neutral pole position Gauche
trigger name Micrologic 4.2
type of trigger Électronique
protected poles 3d + N/2
4d
3d
Complementary
specific differential protection mode Off utilisation de l'interrupteur rotatif IΔn
[ue] rated operational voltage 440 V CA 50/60 Hz
application Distribution
range compatibility ComPacT nouvelle génération NSX160
ComPacT nouvelle génération NSX250
short-time protection threshold setting range [isd] 1,5...10 x Ir
differential protection sensitivity setting range [iОґn] 0,03 A
0,1 A
0,3 A
0,5 A
1 A
3 A
5 A
trigger caliber 250 A à 40 °C
tsd short time protection time delay setting Fixe
setting the differential protection time delay δt Réglable
differential protection time delay setting range [Δt] 0 ms
60 ms
150 ms
500 ms
1 s
iδn differential protection sensitivity adjustment Réglable
network frequency 50/60 Hz
thermal memory 20 minutes avant et après le déclenchement
Local signalling pourprêt à fonctionner DEL clignotante (vert)
poursurcharge DEL 105 % Ir (rouge)
poursurcharge DEL 90 % Ir (orange)
pourcourant résiduel indicateur de couleur (jaune)
long time protection time delay setting range [tr] 11 s à 7,2 x Ir
16 s à 6 x Ir
400 s à 1,5 x Ir
setting range of the long-time protection threshold [ir] (thermal protection) 100...250 A
instantaneous protection threshold setting range [ii] (short-circuit protection) 3000 A
neutral protection setting 0,5 x Ir (3d + N/2)
1 x Ir (4d)
Aucune protection (3d)
Network type Classe A
differential protection Intégrée
tr long time protection time delay setting Fixe
instantaneous protection sensor setting ii (short circuit protection) Fixe
ir long time protection sensor setting (thermal protection) Réglable 9 positions
kind of protection L : for protection surcharge (long retard)
So : for protection court retard avec retard fixe
I : for protection instantanée contre court-circuit
R : for protection différentielle
zsi logic selective latch area Sans
Poles description 4P
Environment
degree of pollution 3 se conformer à CEI 60947-1
ip degree of protection IP40 se conformer à CEI 60529
class of protection against electric shock Classe II
operating ambient temperature -25…70 °C
standards EN/CEI 60947-2
storage room temperature -40…85 °C