All categories
Compare Cart

C1BN2TM10HD - Circuit breaker, ComPacT NSX1200N DC, 50kA/600VDC, 2 poles, TM-DC trip unit 1000A - Schneider Electric

Expected in 2-4 weeks EAN: 3606482005648
C1BN2TM10HD - Circuit breaker, ComPacT NSX1200N DC, 50kA/600VDC, 2 poles, TM-DC trip unit 1000A - Schneider Electric - Circuit breaker, ComPacT NSX1200N DC, 50kA/600VDC, 2 poles, TM-DC trip unit 1000A - Schneider Electric - 0
EAN: 3606482005648
C1BN2TM10HD - Circuit breaker, ComPacT NSX1200N DC, 50kA/600VDC, 2 poles, TM-DC trip unit 1000A - Schneider Electric
2 814,19 €
2 814,19 € incl. VAT
Text About:
Circuit breaker, ComPacT NSX1200N DC, 50kA/600VDC, 2 poles, TM-DC trip unit 1000A - Schneider Electric
2 814,19 €
SPECIFICATIONS
Main
Range ComPacT nouvelle génération
sectioning ability Oui se conformer à EN/CEI 60947-2
job category Catégorie A
name of the device NSX1200 DC
type of product or equipment Disjoncteur
Product Name ComPacT NSX DC nouvelle génération
[ui] rated insulation voltage 750 V CC se conformer à CEI 60947-2
trigger protection functions LI
circuit breaker installation mode Fixe
performance level N 50 kA 600 V CC
trigger name TM-DC
type of trigger Thermique-magnétique
ultimate short-circuit breaking capacity [icu] 50 kA Icu à 24...300 V CC 1 pôle en série se conformer à CEI 60947-2
50 kA Icu à 300...600 V CC 2 pôles en série se conformer à CEI 60947-2
protected poles 2D
Complementary
"no" connection 45 mm
[in] rated operational current 1000 A à 40 °C
[ue] rated operational voltage 600 V CC
application Distribution
[ics] rated service breaking capacity 12,5 kA à 24...300 V CC se conformer à CEI 60947-2
12,5 kA à 300...600 V CC se conformer à CEI 60947-2
Handle front plate colour 350 mm
trigger caliber 1000 A à 40 °C
[uimp] rated impulse withstand voltage 8 kV se conformer à CEI 60947-2
product weight 9,4 kg
electrical life 2000 cycle à 600 V In/2
1000 cycle à 600 V In
mechanical endurance 5000 cycle
width (w) 185 mm
setting range of the long-time protection threshold [ir] (thermal protection) 0,7 à 1 x In
upstream connection Façade
downstream connection Façade
instantaneous protection threshold setting range [ii] (short-circuit protection) 2.5...5 x In
number of slots for electrical auxiliaries 6 slot(s)
mounting bracket Plaque arrière
depth (p) 110 mm
Network type CC
differential protection Sans
mounting position Horizontal et vertical
Flat on the back
tr long time protection time delay setting Fixe
instantaneous protection sensor setting ii (short circuit protection) Réglable
ir long time protection sensor setting (thermal protection) Réglable
order type Par maneton
kind of protection L : for protection surcharge (thermique)
I : for protection (magnétique) court-circuit
Poles description 2P
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 se conformer à CEI 60529
operating altitude 0...2000 m sans réduction de courant
2000 m...5000 m avec réduction de courant
product certificates CCC
EAC
Marine
class of protection against electric shock Classe II
operating ambient temperature -25…70 °C
overvoltage category Classe II
standards EN/CEI 60947
relative humidity 0…95 %
shock resistance ik IK07 se conformer à CEI 62262
storage room temperature -50…85 °C