All categories
Compare Cart

C16B6TM100 - Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 100A - Schneider Electric

Expected in 2-4 weeks
C16B6TM100 - Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 100A - Schneider Electric - Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 100A - Schneider Electric - 0
C16B6TM100 - Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 100A - Schneider Electric
354,83 € excl. VAT
432,89 € incl. VAT
Text About:
Circuit breaker, ComPacT NSX160B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 100A - Schneider Electric
432,89 €
SPECIFICATIONS
Main
Device short name NSX160B
Range ComPacT new generation
circuit breaker mounting mode Fixed
Neutral position Left
Protected poles description 3D
Product Name ComPacT NSX new generation
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 100 A at 40 °C
[ui] rated insulation voltage 800 V AC 50/60 Hz
Trip unit protection functions LI
performance level B 25 kA 415 V AC
Complementary
[ii] instantaneous pick-up adjustment range 800 A
[in] rated current 100 A at 40 °C
[ue] rated operational voltage 690 V AC 50/60 Hz
[ics] rated service breaking capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
depth (d) 86 mm
Product certifications CCC
EAC
Marine
[ir] long-time protection pick-up adjustment range 0.7...1 x In
Connection pitch 35 mm
Handle front plate colour 161 mm
Product or component type Circuit breaker
[uimp] rated impulse withstand voltage 8 kV
[tr] long-time delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Device application Distribution
Electrical shock protection class Class II
width (w) 140 mm
network frequency 50/60 Hz
Ik degree of protection IK07 conforming to IEC 62262
long-time pick-up adjustment type ir (thermal protection) Adjustable
Net weight 2.6 kg
long-time protection delay adjustment type tr Fixed
Downside connection Front
number of slots for electrical auxiliaries 5 slot(s)
Earth-leakage protection Without
Mounting support Backplate
power dissipation per pole 7.7 W
mechanical durability 40000 cycles
neutral protection setting No protection (3D)
electrical durability 40000 cycles at 440 V In/2
20000 cycles at 440 V In
15000 cycles at 690 V In/2
7500 cycles at 690 V In
Network type AC
instantaneous protection pick-up adjustment type ii Fixed
Pollution degree 3 conforming to IEC 60664-1
mounting position Horizontal and vertical
Flat on the back
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 4P
Upside connection Front
Utilisation category Category A
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
operating altitude 0...2000 m without derating
2000 m...5000 m with derating
ambient air temperature for operation -25…70 °C
overvoltage category Class II
standards EN/IEC 60947
relative humidity 0…95 %
Recently viewed
354,83 € excl. VAT
432,89 € incl. VAT
Expected in 2-4 weeks