All categories
Compare Cart

C10L3 - Circuit breaker basic frame, ComPacT NSX100L, 150kA/415VAC, 3 poles, 100A frame rating, without trip unit - Schneider Electric

Expected in 2-4 weeks EAN: 3606481999368
C10L3 - Circuit breaker basic frame, ComPacT NSX100L, 150kA/415VAC, 3 poles, 100A frame rating, without trip unit - Schneider Electric - Circuit breaker basic frame, ComPacT NSX100L, 150kA/415VAC, 3 poles, 100A frame rating, without trip unit - Schneider Electric - 0
EAN: 3606481999368
C10L3 - Circuit breaker basic frame, ComPacT NSX100L, 150kA/415VAC, 3 poles, 100A frame rating, without trip unit - Schneider Electric
312,76 €
312,76 € incl. VAT
Text About:
Circuit breaker basic frame, ComPacT NSX100L, 150kA/415VAC, 3 poles, 100A frame rating, without trip unit - Schneider Electric
312,76 €
SPECIFICATIONS
Main
Range ComPacT nouvelle génération
sectioning ability Oui se conformer à EN/CEI 60947-2
job category Catégorie A
name of the device NSX100L
type of product or equipment Bloc de coupure
Product Name ComPacT NSX nouvelle génération
[ui] rated insulation voltage 800 V CA 50/60 Hz se conformer à CEI 60947-2
performance level L 150 kA 415 V CA
ultimate short-circuit breaking capacity [icu] 130 kA Icu à 440 V CA 50/60 Hz se conformer à CEI 60947-2
150 kA Icu à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
150 kA Icu à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
20 kA Icu à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
50 kA Icu à 525 V CA 50/60 Hz se conformer à CEI 60947-2
70 kA Icu à 500 V CA 50/60 Hz se conformer à CEI 60947-2
Complementary
"no" connection 35 mm
[in] rated operational current 100 A à 40 °C
[ue] rated operational voltage 690 V CA 50/60 Hz se conformer à CEI 60947-2
application Distribution
[ics] rated service breaking capacity 130 kA à 440 V CA 50/60 Hz se conformer à CEI 60947-2
150 kA à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
150 kA à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
20 kA à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
50 kA à 525 V CA 50/60 Hz se conformer à CEI 60947-2
70 kA à 500 V CA 50/60 Hz se conformer à CEI 60947-2
Handle front plate colour 161 mm
[uimp] rated impulse withstand voltage 8 kV se conformer à CEI 60947-2
mechanical life 50000 cycle se conformer à CEI 60947-2
mode d'installation Fixe
electrical life 10000 cycle 690 V CA 50/60 Hz In se conformer à CEI 60947-2
20000 cycle 690 V CA 50/60 Hz In/2 se conformer à CEI 60947-2
30000 cycle 440 V CA 50/60 Hz In se conformer à CEI 60947-2
50000 cycle 440 V CA 50/60 Hz In/2 se conformer à CEI 60947-2
width (w) 105 mm
network frequency 50/60 Hz
upstream connection Façade
downstream connection Façade
mounting bracket Plaque arrière
depth (p) 86 mm
Network type CA
order type Par maneton
kind of protection Sans protection
Poles description 3P
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 se conformer à CEI 60529
product certificates CSA
UL
operating ambient temperature -25…70 °C
standards EN/CEI 60947-2
UL 508
shock resistance ik IK07 se conformer à CEI 62262
storage room temperature -50…85 °C
Recently viewed
312,76 €
312,76 € incl. VAT
Expected in 2-4 weeks