Main
Range
ComPacT nouvelle génération
sectioning ability
Oui se conformer à EN/CEI 60947-2
job category
Catégorie A
name of the device
NSX100H
type of product or equipment
Disjoncteur
Product Name
ComPacT NSX nouvelle génération
[ui] rated insulation voltage
800 V CA 50/60 Hz
trigger protection functions
I
circuit breaker installation mode
Fixe
performance level
H 70 kA 415 V CA
trigger name
MA
type of trigger
Magnétique
ultimate short-circuit breaking capacity [icu]
100 kA Icu à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
70 kA Icu à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
65 kA Icu à 440 V CA 50/60 Hz se conformer à CEI 60947-2
50 kA Icu à 500 V CA 50/60 Hz se conformer à CEI 60947-2
35 kA Icu à 525 V CA 50/60 Hz se conformer à CEI 60947-2
10 kA Icu à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
protected poles
3d
Complementary
"no" connection
35 mm
[in] rated operational current
25 A à 65 °C
[ue] rated operational voltage
690 V CA 50/60 Hz
application
Protection moteur
[ics] rated service breaking capacity
100 kA à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
70 kA à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
65 kA à 440 V CA 50/60 Hz se conformer à CEI 60947-2
50 kA à 500 V CA 50/60 Hz se conformer à CEI 60947-2
35 kA à 525 V CA 50/60 Hz se conformer à CEI 60947-2
10 kA à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
short-time protection threshold setting range [isd]
6...14 x In
Handle front plate colour
161 mm
trigger caliber
25 A à 65 °C
[uimp] rated impulse withstand voltage
8 kV
product weight
2,05 kg
electrical life
50000 cycle à 440 V In/2
30000 cycle à 440 V In
20000 cycle à 690 V In/2
10000 cycle à 690 V In
setting the differential protection time delay δt
Réglable 9 positions
mechanical endurance
50000 cycle
width (w)
105 mm
network frequency
50/60 Hz
upstream connection
Façade
downstream connection
Façade
instantaneous protection threshold setting range [ii] (short-circuit protection)
6...14 x In
number of slots for electrical auxiliaries
5 slot(s)
mounting bracket
Plaque arrière
depth (p)
86 mm
Network type
CA
differential protection
Sans
mounting position
Horizontal et vertical
Flat on the back
power loss per pole
1,04 W
instantaneous protection sensor setting ii (short circuit protection)
Réglable 9 positions
order type
Par maneton
kind of protection
I : for protection (magnétique) court-circuit
Poles description
3P
Environment
degree of pollution
3 se conformer à CEI 60664-1
ip degree of protection
IP40 se conformer à CEI 60529
operating altitude
0...2000 m sans réduction de courant
2000 m...5000 m avec réduction de courant
product certificates
CCC
EAC
Marine
class of protection against electric shock
Classe II
operating ambient temperature
-25…70 °C
overvoltage category
Classe II
standards
EN/CEI 60947
relative humidity
0…95 %
shock resistance ik
IK07 se conformer à CEI 62262
storage room temperature
-50…85 °C