All categories
Compare Cart

C10F2TM080 - Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 80A - Schneider Electric

Expected in 2-4 weeks EAN: 3606481995445
C10F2TM080 - Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 80A - Schneider Electric - Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 80A - Schneider Electric - 0
EAN: 3606481995445
C10F2TM080 - Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 80A - Schneider Electric
135,67 €
135,67 € incl. VAT
Text About:
Circuit breaker, ComPacT NSX100F AC/DC, 18kA/415VAC, 2 poles, TMD trip unit 80A - Schneider Electric
135,67 €
SPECIFICATIONS
Main
Range ComPacT nouvelle génération
sectioning ability Oui se conformer à EN/CEI 60947-2
job category Catégorie A
name of the device NSX100F
type of product or equipment Disjoncteur
Product Name ComPacT NSX nouvelle génération
[ui] rated insulation voltage 750 V CA 50/60 Hz se conformer à CEI 60947-2
trigger protection functions LI
circuit breaker installation mode Fixe
performance level F 18 kA 415 V CA
trigger name TM-D
type of trigger Thermique-magnétique
ultimate short-circuit breaking capacity [icu] 36 kA Icu à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
18 kA Icu à 380/415 V CA 50/60 Hz 1P se conformer à CEI 60947-2
15 kA Icu à 440 V CA 50/60 Hz 1P se conformer à CEI 60947-2
10 kA Icu à 500/525 V CA 50/60 Hz 2P se conformer à CEI 60947-2
5 kA Icu à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
36 kA Icu à 250 V CC 50/60 Hz 1 pôle en série se conformer à CEI 60947-2
36 kA Icu à 500 V CC 50/60 Hz 2 pôles en série se conformer à CEI 60947-2
protected poles 2D
Complementary
"no" connection 35 mm
[in] rated operational current 80 A à 40 °C
[ue] rated operational voltage 690 V CA 50/60 Hz
500 V CC
application Distribution
[ics] rated service breaking capacity 36 kA à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
18 kA à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
15 kA à 440 V CA 50/60 Hz se conformer à CEI 60947-2
10 kA à 500/525 V CA 50/60 Hz se conformer à CEI 60947-2
5 kA à 660/690 V CA 50/60 Hz se conformer à CEI 60947-2
36 kA à 250 V CC 50/60 Hz se conformer à CEI 60947-2
36 kA à 500 V CC 50/60 Hz se conformer à CEI 60947-2
Handle front plate colour 161 mm
trigger caliber 80 A à 40 °C
[uimp] rated impulse withstand voltage 8 kV se conformer à CEI 60947-2
product weight 1,2 kg
electrical life 20000 cycle à 277 V In/2
10000 cycle à 277 V In
mechanical endurance 20000 cycle
width (w) 70 mm
network frequency 50/60 Hz
setting range of the long-time protection threshold [ir] (thermal protection) 1 x In
upstream connection Façade
downstream connection Façade
instantaneous protection threshold setting range [ii] (short-circuit protection) 640 A
mounting bracket Plaque arrière
depth (p) 86 mm
Network type CA
CC
differential protection Sans
mounting position Horizontal et vertical
Flat on the back
power loss per pole 8,77 W
tr long time protection time delay setting Fixe
instantaneous protection sensor setting ii (short circuit protection) Fixe
ir long time protection sensor setting (thermal protection) Fixe
order type Par maneton
kind of protection L : for protection surcharge (thermique)
I : for protection (magnétique) court-circuit
Poles description 2P
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 se conformer à CEI 60529
operating altitude 0...2000 m sans réduction de courant
2000 m...5000 m avec réduction de courant
product certificates CCC
EAC
Marine
class of protection against electric shock Classe II
operating ambient temperature -25…70 °C
overvoltage category Classe II
standards EN/CEI 60947
relative humidity 0…95 %
shock resistance ik IK07 se conformer à CEI 62262
storage room temperature -50…85 °C
Recently viewed
135,67 €
135,67 € incl. VAT
Expected in 2-4 weeks