SPECIFICATIONS
Main
Range ComPacT nouvelle génération
sectioning ability Oui se conformer à EN/CEI 60947-2
job category Catégorie A
name of the device NSX100B
type of product or equipment Disjoncteur différentiel
Product Name ComPacT NSX nouvelle génération
[ui] rated insulation voltage 500 V CA 50/60 Hz
trigger protection functions LSoIR
circuit breaker installation mode Fixe
performance level B 25 kA 415 V CA
trigger name Micrologic 4.2
type of trigger Électronique
ultimate short-circuit breaking capacity [icu] 40 kA Icu à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
25 kA Icu à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
20 kA Icu à 440 V CA 50/60 Hz se conformer à CEI 60947-2
15 kA Icu à 500 V CA 50/60 Hz se conformer à CEI 60947-2
protected poles 3d
Complementary
"no" connection 35 mm
specific differential protection mode Off utilisation de l'interrupteur rotatif IΔn
[in] rated operational current 100 A à 40 °C
[ue] rated operational voltage 440 V CA 50/60 Hz
application Distribution
[ics] rated service breaking capacity 40 kA à 220/240 V CA 50/60 Hz se conformer à CEI 60947-2
25 kA à 380/415 V CA 50/60 Hz se conformer à CEI 60947-2
20 kA à 440 V CA 50/60 Hz se conformer à CEI 60947-2
7 kA à 500 V CA 50/60 Hz se conformer à CEI 60947-2
short-time protection threshold setting range [isd] 1,5...10 x Ir
differential protection sensitivity setting range [iОґn] 30 mA
100 mA
300 mA
500 mA
1 A
3 A
5 A
Handle front plate colour 161 mm
trigger caliber 100 A à 40 °C
[uimp] rated impulse withstand voltage 8 kV
product weight 2,05 kg
tsd short time protection time delay setting Fixe
electrical life 50000 cycle à 440 V In/2
30000 cycle à 440 V In
20000 cycle à 690 V In/2
10000 cycle à 690 V In
setting the differential protection time delay δt Réglable
differential protection time delay setting range [Δt] 0 ms
60 ms
150 ms
500 ms
1 s
mechanical endurance 50000 cycle
width (w) 105 mm
iδn differential protection sensitivity adjustment Réglable
network frequency 50/60 Hz
thermal memory 20 minutes avant et après le déclenchement
Local signalling pourprêt à fonctionner DEL clignotante (vert)
poursurcharge DEL 105 % Ir (rouge)
poursurcharge DEL 90 % Ir (orange)
long time protection time delay setting range [tr] 400 s à 1,5 x Ir
16 s à 6 x Ir
11 s à 7,2 x Ir
short time protection time delay setting range [tsd] 0,02 s
setting range of the long-time protection threshold [ir] (thermal protection) 40...100 A
upstream connection Façade
downstream connection Façade
instantaneous protection threshold setting range [ii] (short-circuit protection) 1500 A
number of slots for electrical auxiliaries 5 slot(s)
mounting bracket Plaque arrière
depth (p) 86 mm
Network type Classe A
differential protection Intégrée
mounting position Horizontal et vertical
Flat on the back
power loss per pole 5,8 W N
5,8 W L1 et L3
3,9 W L2
tr long time protection time delay setting Fixe
instantaneous protection sensor setting ii (short circuit protection) Fixe
ir long time protection sensor setting (thermal protection) Réglable 9 positions
order type Par maneton
kind of protection L : for protection surcharge (long retard)
So : for protection court retard avec retard fixe
I : for protection instantanée contre court-circuit
R : for protection différentielle
zsi logic selective latch area Sans
Poles description 3P
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 se conformer à CEI 60529
operating altitude 0...2000 m sans réduction de courant
2000 m...5000 m avec réduction de courant
product certificates CCC
EAC
Marine
class of protection against electric shock Classe II
operating ambient temperature -25…70 °C
overvoltage category Classe II
standards EN/CEI 60947
relative humidity 0…95 %
shock resistance ik IK07 se conformer à CEI 62262
storage room temperature -50…85 °C