All categories
Compare Cart

BMXCPS4022H - Redundant power supply module X80 24..48 V DC for severe environments - Schneider Electric

Expected in 2-4 weeks
BMXCPS4022H - Redundant power supply module X80 24..48 V DC for severe environments - Schneider Electric - Redundant power supply module X80 24..48 V DC for severe environments - Schneider Electric - 0
BMXCPS4022H - Redundant power supply module X80 24..48 V DC for severe environments - Schneider Electric
1 118,80 € excl. VAT
1 364,93 € incl. VAT
Text About:
Redundant power supply module X80 24..48 V DC for severe environments - Schneider Electric
1 364,93 €
SPECIFICATIONS
Main
Advanced diagnostics available via network Temperature sensing
Uptime duration
Redundancy test
Remaining lifetime
Redundancy information
Backplane compatibility All backplane
Primary voltage 24...48 V
product specific application For severe environments
Secondary power 18 W 3.3 V DC at -25…70 °C I/O module logic power supply
40 W 24 V DC at -25…70 °C I/O module power supply and processor if 3.3 V not loaded
i²t at switch-on 1 A².s 24 V
3 A².s 48 V
Complementary
Control type RESET push-button cold restart
Product certifications CE
UL
CSA
RCM
EAC
Merchant Navy
ATEX zone 2/22
IECEx zone 2/22
Current at secondary voltage 5.5 A 3.3 V DC I/O module logic power supply
1.67 A 24 V DC I/O module power supply and processor
mtbf reliability 752000 H
Product or component type Power supply module
inrush current 60 A 48 V
60 A 24 V
maximum power dissipation in w 8.5 W
input current 1.9 A 24 V
1 A 48 V
It on activation 0.3 A.s 24 V
0.4 A.s 48 V
Net weight 0.81 kg
Maximum cable distance between devices 10 m
15 m
Immunity to microbreaks 1 ms
Primary voltage limit 18...62.4 V
electrical connection 1 connector 2 pin(s)alarm relay
1 connector 5 pin(s)line supply, protective earth
dielectric strength 1500 V primary/ground
1500 V primary/secondary
Status led 1 LED (green) presence of voltages (OK)
1 LED (green) redundancy OK
1 LED (green) power supply status
Supply circuit type DC
Protection type Internal fuse not accessible for primary circuit
Overload protection for secondary circuit
Overvoltage protection for secondary circuit
Short-circuit protection for secondary circuit
Environment
Ambient air temp for storage/transportation -40…85 °C
Directives 2014/35/EU - low voltage directive
2014/30/EU - electromagnetic compatibility
2014/34/EU - ATEX directive
ip degree of protection IP20
Range of product Modicon X80
ambient air temperature for operation -25…70 °C
Environmental characteristics Gas resistant class Gx conforming to ISA S71.04
Gas resistant class 3C4 conforming to IEC 60721-3-3
Dust resistant class 3S4 conforming to IEC 60721-3-3
Sand resistant class 3S4 conforming to IEC 60721-3-3
Salt resistant level 2 conforming to IEC 68252
Mold growth resistant class 3B2 conforming to IEC 60721-3-3
Fungal spore resistant class 3B2 conforming to IEC 60721-3-3
Hazardous location class I division 2
standards EN/IEC 61131-2
EN/IEC 61010-2-201
UL 61010-2-201
CSA C22.2 No 61010-2-201
IACS E10
EN/IEC 61000-6-5, interface type 1 and type 2
EN/IEC 61850-3, location G
EN/IEC 60079-0
relative humidity 10…95 % without condensation
protective treatment Conformal coating
insulation resistance >= 100 MOhm primary/ground
>= 100 MOhm primary/secondary