All categories
Compare Cart

BMXCPS4002 - Power supply module X80 100..240 V AC - Schneider Electric

Expected in 2-4 weeks
BMXCPS4002 - Power supply module X80 100..240 V AC - Schneider Electric - Power supply module X80 100..240 V AC - Schneider Electric - 0
BMXCPS4002 - Power supply module X80 100..240 V AC - Schneider Electric
1 165,70 €
1 165,70 € incl. VAT
Text About:
Power supply module X80 100..240 V AC - Schneider Electric
1 165,70 €
SPECIFICATIONS
Main
Advanced diagnostics available via network Temperature sensing
Redundancy test
Uptime duration
Redundancy information
Remaining lifetime
Backplane compatibility All backplane
Primary voltage 100...240 V
Secondary power 18 W 3.3 V DC at 0…60 °C I/O module logic power supply
40 W 24 V DC at 0…60 °C I/O module power supply and processor if 3.3 V not loaded
i²t at switch-on 1 A².s 115 V
4 A².s 230 V
Complementary
Control type RESET push-button cold restart
Current at secondary voltage 5.5 A 3.3 V DC I/O module logic power supply
1.67 A 24 V DC I/O module power supply and processor
mtbf reliability 792000 H
Product or component type Power supply module
inrush current 30 A 120 V
60 A 240 V
network frequency limits 47…63 Hz
maximum power dissipation in w 8.5 W
input current 0.52 A 240 V
1.04 A 115 V
network frequency 50/60 Hz
It on activation 0.1 A.s 115 V
0.15 A.s 230 V
Net weight 0.51 kg
Immunity to microbreaks 1 ms
Primary voltage limit 85...264 V
electrical connection 1 connector 2 pin(s)alarm relay
1 connector 5 pin(s)line supply, protective earth
dielectric strength 1500 V primary/secondary I/O module logic power supply
1500 V primary/secondary I/O module power supply and processor
2300 V primary/secondary sensor power supply
1500 V primary/ground
500 V 24 V sensor output/ground
Shock resistance 30 gn
Status led 1 LED (green) presence of voltages (OK)
1 LED (green) redundancy OK
1 LED (green) power supply status
apparent power 0.13 kVA
Supply circuit type AC
Protection type Internal fuse not accessible for primary circuit
Overload protection for secondary circuit
Overvoltage protection for secondary circuit
Short-circuit protection for secondary circuit
Environment
Ambient air temp for storage/transportation -40…85 °C
Directives 2014/35/EU - low voltage directive
2014/30/EU - electromagnetic compatibility
ip degree of protection IP20
operating altitude 0...2000 m
2000...5000 m with derating factor
Range of product Modicon X80
ambient air temperature for operation 0…60 °C
Environmental characteristics 3C3 conforming to EN/IEC 60721-3-3
3C4 conforming to EN/IEC 60721-3-3
relative humidity 5…95 % at 55 °C without condensation
vibration resistance 3 gn
protective treatment TC
Conformal coating Humiseal 1A33
insulation resistance >= 100 MOhm primary/ground
>= 100 MOhm primary/secondary
Recently viewed
1 165,70 €
1 165,70 € incl. VAT
Expected in 2-4 weeks