ATV650U75N4 - Variable speed drive, Altivar Process ATV600, ATV650, 7.5 kW, 400...480 V, IP55 - Schneider Electric

Expected in 2-4 weeks
ATV650U75N4 - Variable speed drive, Altivar Process ATV600, ATV650, 7.5 kW, 400...480 V, IP55 - Schneider Electric - Variable speed drive, Altivar Process ATV600, ATV650, 7.5 kW, 400...480 V, IP55 - Schneider Electric - 0
ATV650U75N4 - Variable speed drive, Altivar Process ATV600, ATV650, 7.5 kW, 400...480 V, IP55 - Schneider Electric
1 503,38 € excl. VAT
1 834,12 € incl. VAT
Text About:
Variable speed drive, Altivar Process ATV600, ATV650, 7.5 kW, 400...480 V, IP55 - Schneider Electric
1 834,12 €
SPECIFICATIONS
Main
Device short name ATV650
product specific application Process and utilities
Safety function STO (safe torque off) SIL 3
emc filter Integrated with 50 m conforming to EN/IEC 61800-3 category C2
Integrated with 150 m conforming to EN/IEC 61800-3 category C3
motor power kW 5.5 kW (heavy duty)
7.5 kW (normal duty)
variant Standard version
Complementary
Accuracy +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Product certifications UL
CSA
Bureau Veritas
ABS
TÜV
ATEX INERIS
TÜV
data formats 8 bits, configurable odd, even or no parity
Handle front plate colour 678 mm
Product or component type Variable speed drive
[us] rated supply voltage 380...480 V - 15...10 %
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
noise level 52 dB
marking CE
Quantity per set 1
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Analogue output number 2
Asynchronous motor control profile Variable torque standard
Optimized torque mode
Optimized torque mode
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
output voltage <= power supply voltage
width (w) 264 mm
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Discrete input type DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
isolation Between power and control terminals
switching frequency 4...12 kHz with derating factor
2...12 kHz adjustable
Local signalling 3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
3 LEDs for local diagnostic
motor slip compensation Can be suppressed
Not available in permanent magnet motor law
Automatic whatever the load
Automatic whatever the load
Mounting mode Wall mount
Braking to standstill By DC injection
Discrete input number 8
Net weight 13.7 kg
physical interface Ethernet
2-wire RS 485
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Operating position Vertical +/- 10 degree
communication port protocol Modbus serial
Ethernet
Modbus serial
Motor power hp 5 hp heavy duty
10 hp normal duty
connector type RJ45 (on the remote graphic terminal) for Modbus serial
RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
depth 299 mm
line current 9.1 A at 480 V (normal duty)
8 A at 380 V (heavy duty)
7.2 A at 480 V (heavy duty)
13.8 A at 380 V (normal duty)
continuous output current 9.3 A at 4 kHz for heavy duty
16.5 A at 4 kHz for normal duty
Motor power range ac-3 7…11 kW at 380…440 V 3 phases
maximum transient current 14 A during 60 s (heavy duty)
18.2 A during 60 s (normal duty)
Permissible temporary current boost 1.5 x In during 60 s (heavy duty)
1.1 x In during 60 s (normal duty)
Pollution degree 3
electrical connection Line side: screw terminal 4...6 mm²/AWG 12...AWG10
Motor: screw terminal 4...6 mm²/AWG 12...AWG10
Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16
linearity error AO1, AO2: +/- 0.2 % for analog output
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Network number of phases 3 phases
nominal switching frequency 4 kHz
Enclosure mounting Wall mounted
maximum output frequency 500 kHz
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Input compatibility DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
Product destination Asynchronous motors
Synchronous motors
Maximum input current 13.8 A
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Method of access Slave Modbus TCP
synchronous motor control profile Synchronous reluctance motor
Permanent magnet motor
Supply frequency 50...60 Hz - 5...5 %
apparent power 6 kVA at 480 V (heavy duty)
9.9 kVA at 480 V (normal duty)
number of addresses 1…247 for Modbus serial
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
variable speed drive application selection Building - HVAC compressor centrifugal
acceleration and deceleration ramps Linear adjustable separately from 0.01...9999 s
Protection type Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Thermal protection: motor
Option card Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Slot A: communication module, Profibus DP V1
relay output type Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Transmission rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Type of cooling Forced convection
frequency resolution Analog input: 0.012/50 Hz
Display unit: 0.1 Hz
Prospective line isc 50 kA
transmission frame RTU
Relay output number 3
Sampling duration 5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AO1) - analog output
2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Speed drive output frequency 0.1…500 Hz
Type of polarization No impedance
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP55 conforming to IEC 60529
IP55 conforming to IEC 61800-5-1
operating altitude 1000...4800 m with current derating 1 % per 100 m
<= 1000 m without derating
Range of product Altivar Process ATV600
ambient air temperature for operation 40…50 °C (with derating factor)
-15…40 °C (without derating)
electromagnetic compatibility Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
overvoltage category III
standards EN/IEC 61800-3
EN/IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
UL 508C
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Maximum thdi <48 % from 80...100 % of load conforming to IEC 61000-3-12
Regulation loop Adjustable PID regulator
vibration resistance 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth