All categories
Compare Cart

ATV630D30Y6 - Variable speed drive, Altivar Process ATV600, ATV630, 30kW/40 hp, 500V/690 V, IP00 - Schneider Electric

Expected in 2-4 weeks
ATV630D30Y6 - Variable speed drive, Altivar Process ATV600, ATV630, 30kW/40 hp, 500V/690 V, IP00 - Schneider Electric - Variable speed drive, Altivar Process ATV600, ATV630, 30kW/40 hp, 500V/690 V, IP00 - Schneider Electric - 0
ATV630D30Y6 - Variable speed drive, Altivar Process ATV600, ATV630, 30kW/40 hp, 500V/690 V, IP00 - Schneider Electric
3 759,62 €
3 759,62 € incl. VAT
Text About:
Variable speed drive, Altivar Process ATV600, ATV630, 30kW/40 hp, 500V/690 V, IP00 - Schneider Electric
3 759,62 €
SPECIFICATIONS
Main
Device short name ATV630
product specific application Process and utilities
Safety function STO (safe torque off) SIL 3
emc filter Integrated with 25 m conforming to EN/IEC 61800-3 category C3
motor power kW 22 kW at 500 V (normal duty)
18.5 kW at 500 V (heavy duty)
30 kW at 690 V (normal duty)
22 kW at 690 V (heavy duty)
variant Standard version
Complementary
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Product certifications UL
CSA
TÜV
data formats 8 bits, configurable odd, even or no parity
Handle front plate colour 420 mm
Product or component type Variable speed drive
[us] rated supply voltage 500...690 V - 15...10 %
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
noise level 58 dB
marking CE
Quantity per set 1
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Analogue output number 2
Asynchronous motor control profile Constant torque standard
Optimized torque mode
Variable torque standard
Discrete input logic Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
output voltage <= power supply voltage
width (w) 246 mm
Analogue output type Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Discrete input type DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
isolation Between power and control terminals
switching frequency 2...8 kHz adjustable
4...8 kHz with derating factor
Local signalling 3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
motor slip compensation Not available in permanent magnet motor law
Can be suppressed
Adjustable
Automatic whatever the load
Mounting mode Wall mount
Braking to standstill By DC injection
Discrete input number 8
Net weight 22 kg
physical interface Ethernet
2-wire RS 485
Discrete output type Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Operating position Vertical +/- 10 degree
communication port protocol Ethernet
Modbus serial
Modbus TCP
Motor power hp 30 hp at 500 V normal duty
25 hp at 500 V heavy duty
40 hp at 690 V normal duty
30 hp at 690 V heavy duty
connector type RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial
depth 242 mm
line current 32.1 A at 500 V (normal duty)
32.8 A at 690 V (normal duty)
27.6 A at 500 V (heavy duty)
26 A at 690 V (heavy duty)
power dissipation in w Natural convection: 152 W at 500 V, switching frequency 4 kHz
Forced convection: 544 W at 500 V, switching frequency 4 kHz
continuous output current 34 A at 4 kHz for normal duty
29 A at 4 kHz for heavy duty
maximum transient current 37.4 A during 60 s (normal duty)
43.5 A during 60 s (heavy duty)
Permissible temporary current boost 1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
Pollution degree 2
electrical connection Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16
Motor: screw terminal 10 mm²/AWG 8
Line side: screw terminal 10 mm²/AWG 8
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output
Network number of phases 3 phases
nominal switching frequency 4 kHz
Enclosure mounting Wall mounted
maximum output frequency 500 kHz
Exchange mode Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Input compatibility DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Product destination Asynchronous motors
Synchronous motors
Maximum input current 32.8 A
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Method of access Slave Modbus TCP
synchronous motor control profile Permanent magnet motor
Synchronous reluctance motor
Supply frequency 50...60 Hz - 5...5 %
apparent power 39.2 kVA at 690 V (normal duty)
31.1 kVA at 690 V (heavy duty)
number of addresses 1…247 for Modbus serial
Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
acceleration and deceleration ramps S, U or customized
Linear adjustable separately from 0.01...9999 s
Protection type Thermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Option card Slot A: communication module, Profibus DP V1
Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Transmission rate 10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Type of cooling Forced convection
frequency resolution Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
Prospective line isc 70 kA
transmission frame RTU
Relay output number 3
Sampling duration 2 ms +/- 0.5 ms (DI1...DI4) - discrete input
5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AO1) - analog output
Speed drive output frequency 0.1…500 Hz
Type of polarization No impedance
Volume of cooling air 330 m3/h
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP00 conforming to IEC 61800-5-1
IP00 conforming to IEC 60529
IP20 (with kit VW3A9706) conforming to IEC 61800-5-1
IP20 (with kit VW3A9706) conforming to IEC 60529
operating altitude <= 1000 m without derating
1000...4800 m with current derating 1 % per 100 m
Range of product Altivar Process ATV600
ambient air temperature for operation -15…50 °C (without derating)
50…60 °C (with derating factor)
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
overvoltage category III
standards UL 508C
EN/IEC 61800-3
EN/IEC 61800-3 environment 2 category C3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Maximum thdi <48 % with external line choke conforming to IEC 61000-3-12
Regulation loop Adjustable PID regulator
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
Recently viewed
3 759,62 €
3 759,62 € incl. VAT
Expected in 2-4 weeks