All categories
Compare Cart

ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric

Expected in 2-4 weeks EAN: 3606480966774
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 0
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 1
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 2
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 3
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 4
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 5
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 6
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 7
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 8
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric - 9
EAN: 3606480966774
ATV320U30N4C - Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric
521,91 € excl. VAT
636,73 € incl. VAT
Text About:
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact - Schneider Electric
636,73 €
SPECIFICATIONS
Main
product range Altivar Machine ATV320
product specific application Machines complexes
option board Module de communication, CANopen
Module de communication, EtherCAT
Module de communication, Profibus DP V1
Module de communication, Profinet
Module de communication, Ethernet Powerlink
Module de communication, Ethernet IP
Module de communication, DeviceNet
type of product or equipment Variateur de vitesse
rated output current 7,1 A
emc filter Filtre intégré CEM Classe C2
drive size Compact
communication protocol Modbus série
CANopen
motor power kW 3,0 kW pour surcharge importante
variant Version standard
Complementary
4 quadrant operation possible Vrai
with safety function safe brake management (sbc/sbt) Faux
[un] rated nominal voltage 380…500 V - 15...10 %
with safe direction (sdi) safety function Faux
maximum switching current Sortie relais R1A, R1B, R1C sur résistive charge, cos phi = 1: 3 A à 250 V AC
Sortie relais R1A, R1B, R1C sur résistive charge, cos phi = 1: 3 A à 30 V CC
Sortie relais R1A, R1B, R1C, R2A, R2C sur inductive charge, cos phi = 0,4 et L/R = 7 ms: 2 A à 250 V AC
Sortie relais R1A, R1B, R1C, R2A, R2C sur inductive charge, cos phi = 0,4 et L/R = 7 ms: 2 A à 30 V CC
Sortie relais R2A, R2C sur résistive charge, cos phi = 1: 5 A à 250 V AC
Sortie relais R2A, R2C sur résistive charge, cos phi = 1: 5 A à 30 V CC
with safety function safe operating stop (sos) Faux
Handle front plate colour 184,0 mm
with safe position (sp) safety function Faux
with safety function safe programmable logic Faux
minimum switching current Sortie relais R1A, R1B, R1C, R2A, R2C: 5 mA à 24 V CC
product weight 2,1 kg
with safe speed monitor (ssm) safety function Faux
marking CE
ATEX
UL
CSA
EAC
RCM
mode d'installation Montage au mur
with safety function safe stop 1 (ss1) Vrai
with safety function safe stop 2 (ss2) Faux
with safe torque off (sto) safety function Vrai
width (w) 140 mm
with safely limited position (slp) safety function Faux
network frequency 50...60 Hz
switching frequency 2...16 kHz réglable
4...16 kHz avec facteur de réduction
with safety function safely limited speed (sls) Vrai
motor slip compensation Automatique quelque soit la charge
Réglable 0…300 %
Non disponible en rapport tension/fréquence (2 ou 5 points)
base load current at high overload 7,1 A
prospective line short-circuit current 5 kA
depth 158,0 mm
line current 11,1 A à 380 V (surcharge importante)
8,4 A à 500 V (surcharge importante)
power dissipation in w Ventilateur: 93,0 W à 380 V, fréquence de commutation 4 kHz
current maximum input current per phase 11,1 A
logic input Logique positive (source)
Logique négative (sink)
standstill braking 4 x 2,5 mm² + 2 x 1 mm² + 2 x 0,14 mm²
mounting position Vertical +/- 10 degrés
nominal switching frequency 4 kHz
maximum output frequency 0,599 kHz
kind of protection Coupures de phase en entrée: variateur
Surintensité entre phases de sortie et terre: variateur
Protection surchauffe: variateur
Court-circuit entre les phases du moteur: variateur
Protection thermique: variateur
access method Esclave CANopen
number of analog inputs 3
number of logic inputs 7
number of analog outputs 1
number of logic outputs 3
synchronous motor control profile Contrôle vectoriel sans capteur
control profile for asynchronous motor Rapport tension/fréquence, 5 points
Commande vecteur de flux sans capteur, standard
Rapport tension/fréquence - Économie d'énergie, U/f quadratique
Contrôle vectoriel de flux sans capteur - Economie d'énergie
Rapport tension/fréquence, 2 points
apparent power 7,3 kVA à 500 V (surcharge importante)
acceleration and deceleration ramps Linéaire
U
S
CUS
Commutation de rampe
Adaptation rampe accélération/décélération
Accélération/décélération arrêt automatique avec injection DC
integrated braking resistor Vrai
transient overtorque 170…200 % du couple nominal du moteur
max output voltage 500 V
symmetric network relative frequency tolerance 5 %
analog input type AI1 tension: 0...10 V CC, impédance: 30 kOhm, résolution 10 bits
AI2 tension différentielle bipolaire: +/- 10 V CC, impédance: 30 kOhm, résolution 10 bits
AI3 courant: 0…20 mA (ou 4-20 mA, x-20 mA, 20-x mA ou autres modèles par configuration), impédance: 250 Ohm, résolution 10 bits
logic input type STO suppression sûre du couple, 24 V CC, impédance: 1,5 kOhm
DI1…DI6 entrées logiques, 24 V CC (30 V)
DI5 programmable comme entrée en train d'impulsions: 0…30 kHz, 24 V CC (30 V)
analog output type Courant configurable par logiciel AQ1: 0...20 mA impedance 800 Ohm, résolution 10 bits
Tension configurable par logiciel AQ1: 0...10 V CC impedance 470 Ohm, résolution 10 bits
logic output type Collecteur ouvert DQ+ 0…1 kHz 30 V CC 100 mA
Collecteur ouvert DQ- 0…1 kHz 30 V CC 100 mA
relay output type Relais configurable R1A 1 "F" durabilité électrique 100000 cycle
Relais configurable R1B 1 "O" durabilité électrique 100000 cycle
Relais configurable R1C
Relais configurable R2A 1 "F" durabilité électrique 100000 cycle
Relais configurable R2A
Environment
Ambient air temp for storage/transportation -25…70 °C
degree of pollution 2
ip degree of protection IP20
maximum shock acceleration (in operation) 150 m/s² à 11 ms
product certificates CE
ATEX
NOM
GOST
EAC
RCM
KC
electromagnetic compatibility Test d'immunité aux décharges électrostatiques niveau 3 se conformer à CEI 6100-4-11
Test d'immunité aux champs électromagnétiques radio-fréquences rayonnés niveau 3 se conformer à CEI 61000-4-3
Test d'immunité aux transitoires électriques rapides niveau 4 se conformer à CEI 61000-4-4
Test d'immunité aux surtensions 1,2/50 µs - 8/20 µs niveau 3 se conformer à CEI 61000-4-5
Test d'immunité aux radio-fréquences conduites niveau 3 se conformer à CEI 61000-4-6
Test d'immunité aux baisses et aux interruptions de tension se conformer à CEI 61000-4-11
maximum acceleration under vibration stress (in operation) 10 m/s² à 13...200 Hz
overvoltage category III
standards EN/CEI 61800-5-1
control loop Régulateur PID réglable
operating temperature -10…50 °C sans déclassement
50…60 °C avec facteur de réduction
storage room temperature -25…70 °C
environmental class (in operation) Classe 3C3 selon CEI 60721-3-3
Classe 3S2 selon CEI 60721-3-3
air flow 37,7 m3/h
maximum deflection under vibration load (in operation) 1,5 mm à 2...13 Hz
permissible relative humidity (during operation) Classe 3K5 selon EN 60721-3
speed accuracy +/-10% du glissement nominal 0,2 Tn à Tn