ATV212HD30M3X - Variable speed drive ATV212 30kW 40hp 240V 3ph wo EMC IP21 - Schneider Electric

Expected in 2-4 weeks
ATV212HD30M3X - Variable speed drive ATV212 30kW 40hp 240V 3ph wo EMC IP21 - Schneider Electric - Variable speed drive ATV212 30kW 40hp 240V 3ph wo EMC IP21 - Schneider Electric - 0
ATV212HD30M3X - Variable speed drive ATV212 30kW 40hp 240V 3ph wo EMC IP21 - Schneider Electric
3 243,48 €
3 243,48 € incl. VAT
Text About:
Variable speed drive ATV212 30kW 40hp 240V 3ph wo EMC IP21 - Schneider Electric
3 243,48 €
SPECIFICATIONS
Main
Device short name ATV212
product specific application Pumps and fans in HVAC
emc filter Without EMC filter
motor power kW 30 kW
Complementary
specific application HVAC
Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 1 % (FM) for a temperature variation 60 °C
maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
Product certifications NOM 117
CSA
C-Tick
UL
response time FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
data formats 8 bits, 1 stop, odd even or no configurable parity
Handle front plate colour 630 mm
Product or component type Variable speed drive
tightening torque 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
41 N.m, 360 lb.in (L1/R, L2/S, L3/T)
[us] rated supply voltage 200...240 V - 15...10 %
Assembly style With heat sink
minimum switching current 3 mA at 24 V DC for configurable relay logic
noise level 63.7 dB conforming to 86/188/EEC
marking CE
Analogue input number 2
Analogue input type VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm
VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Asynchronous motor control profile Voltage/frequency ratio, 2 points
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Discrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
output voltage <= power supply voltage
width (w) 320 mm
Analogue output type FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits
FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits
Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
isolation Electrical between power and control
network frequency 47.5...63 Hz
supply voltage limits 170…264 V
switching frequency 6...16 kHz adjustable
8...16 kHz with derating factor
Local signalling 1 LED (red) for DC bus energized
motor slip compensation Not available in voltage/frequency ratio motor control
Adjustable
Automatic whatever the load
Braking to standstill By DC injection
Net weight 38.65 kg
physical interface 2-wire RS 485
Discrete output type Configurable relay logic: (FLA, FLC) NO - 100000 cycles
Configurable relay logic: (FLB, FLC) NC - 100000 cycles
Configurable relay logic: (RY, RC) NO - 100000 cycles
Communication service Write multiple registers (16) 2 words maximum
Monitoring inhibitable
Time out setting from 0.1 to 100 s
Read holding registers (03) 2 words maximum
Read device identification (43)
Write single register (06)
Operating position Vertical +/- 10 degree
communication port protocol METASYS N2
APOGEE FLN
BACnet
LonWorks
Modbus
Discrete output number 2
Motor power hp 40 hp
connector type 1 RJ45
1 open style
depth 290 mm
line current 113.3 A at 200 V
89.5 A at 240 V
power dissipation in w 1085 W
continuous output current 117 A at 230 V
Motor power range ac-3 30…50 kW at 200…240 V 3 phases
maximum transient current 128.7 A for 60 s
Pollution degree 3 conforming to IEC 61800-5-1
electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
L1/R, L2/S, L3/T: terminal 150 mm² (300 kcmil)
linearity error VIA: +/- 0.15 % of maximum value for input
VIB: +/- 0.15 % of maximum value for input
FM: +/- 0.2 % for output
Network number of phases 3 phases
nominal switching frequency 8 kHz
dielectric strength 2830 V DC between earth and power terminals
4230 V DC between control and power terminals
motor starter type Variable speed drive
Product destination Asynchronous motors
speed range 1…10
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Supply frequency 50...60 Hz - 5...5 %
torque accuracy +/- 15 %
apparent power 44.6 kVA at 240 V
number of addresses 1…247
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
variable speed drive application selection Building - HVAC compressor for scroll
Building - HVAC fan
Building - HVAC pump
acceleration and deceleration ramps Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s
Protection type Overheating protection: drive
Thermal power stage: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply overvoltage and undervoltage: drive
Line supply undervoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
With PTC probes: motor
Option card Communication card for LonWorks
Transmission rate 9600 bps or 19200 bps
frequency resolution Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
Prospective line isc 22 kA
transmission frame RTU
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Speed drive output frequency 0.5…200 Hz
Type of polarization No impedance
Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Environment
Ambient air temp for storage/transportation -25…70 °C
ip degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1
IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
IP21 conforming to EN/IEC 61800-5-1
IP21 conforming to EN/IEC 60529
IP41 on upper part conforming to EN/IEC 61800-5-1
IP41 on upper part conforming to EN/IEC 60529
operating altitude 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
<= 1000 m without derating
Range of product Altivar 212
ambient air temperature for operation -10…40 °C (without derating)
40…50 °C (with derating factor)
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental characteristics Classes 3C1 conforming to IEC 60721-3-3
Classes 3S2 conforming to IEC 60721-3-3
standards IEC 61800-3 environments 2 category C1
IEC 61800-3 environments 2 category C2
IEC 61800-3 environments 1 category C2
EN 61800-3
IEC 61800-5-1
EN 61800-3 environments 1 category C3
EN 61800-3 environments 1 category C1
UL Type 1
EN 61800-3 environments 1 category C2
IEC 61800-3 environments 1 category C1
IEC 61800-3 environments 2 category C3
EN 61800-3 environments 2 category C1
IEC 61800-3 environments 1 category C3
IEC 61800-3
EN 61800-3 environments 2 category C3
EN 61800-3 environments 2 category C2
EN 61800-5-1
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Regulation loop Adjustable PI regulator
vibration resistance 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
air flow 371 m3/h
insulation resistance >= 1 mOhm 500 V DC for 1 minute
speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn