All categories
Compare Cart

ATV212H075M3X - Variable speed drive ATV212 0.75kW 1hp 240V 3ph wo EMC IP21 - Schneider Electric

Expected in 2-4 weeks
ATV212H075M3X - Variable speed drive ATV212 0.75kW 1hp 240V 3ph wo EMC IP21 - Schneider Electric - Variable speed drive ATV212 0.75kW 1hp 240V 3ph wo EMC IP21 - Schneider Electric - 0
ATV212H075M3X - Variable speed drive ATV212 0.75kW 1hp 240V 3ph wo EMC IP21 - Schneider Electric
345,00 €
345,00 € incl. VAT
Text About:
Variable speed drive ATV212 0.75kW 1hp 240V 3ph wo EMC IP21 - Schneider Electric
345,00 €
SPECIFICATIONS
Main
Device short name ATV212
product specific application Pumps and fans in HVAC
emc filter Without EMC filter
motor power kW 0.75 kW
Complementary
specific application HVAC
Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 1 % (FM) for a temperature variation 60 °C
maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
Product certifications C-Tick
UL
NOM 117
CSA
response time FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
data formats 8 bits, 1 stop, odd even or no configurable parity
Handle front plate colour 143 mm
Product or component type Variable speed drive
tightening torque 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T)
0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
[us] rated supply voltage 200...240 V - 15...10 %
Assembly style With heat sink
minimum switching current 3 mA at 24 V DC for configurable relay logic
noise level 51 dB conforming to 86/188/EEC
marking CE
Analogue input number 2
Analogue input type VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm
VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Asynchronous motor control profile Voltage/frequency ratio, 2 points
Voltage/frequency ratio - Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Discrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
output voltage <= power supply voltage
width (w) 107 mm
Analogue output type FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits
FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits
Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
isolation Electrical between power and control
network frequency 47.5...63 Hz
supply voltage limits 170…264 V
switching frequency 6...16 kHz adjustable
12...16 kHz with derating factor
Local signalling 1 LED (red) for DC bus energized
motor slip compensation Automatic whatever the load
Adjustable
Not available in voltage/frequency ratio motor control
Braking to standstill By DC injection
Net weight 1.8 kg
physical interface 2-wire RS 485
Discrete output type Configurable relay logic: (FLA, FLC) NO - 100000 cycles
Configurable relay logic: (FLB, FLC) NC - 100000 cycles
Configurable relay logic: (RY, RC) NO - 100000 cycles
Communication service Read holding registers (03) 2 words maximum
Write multiple registers (16) 2 words maximum
Write single register (06)
Time out setting from 0.1 to 100 s
Monitoring inhibitable
Read device identification (43)
Operating position Vertical +/- 10 degree
communication port protocol LonWorks
Modbus
APOGEE FLN
METASYS N2
BACnet
Discrete output number 2
Motor power hp 1 hp
connector type 1 RJ45
1 open style
depth 150 mm
line current 2.7 A at 240 V
3.3 A at 200 V
power dissipation in w 63 W
continuous output current 4.6 A at 230 V
Motor power range ac-3 0.55…1 kW at 200…240 V 3 phases
maximum transient current 5.1 A for 60 s
Pollution degree 2 conforming to IEC 61800-5-1
electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
L1/R, L2/S, L3/T: terminal 6 mm² / AWG 10
linearity error VIA: +/- 0.15 % of maximum value for input
VIB: +/- 0.15 % of maximum value for input
FM: +/- 0.2 % for output
Network number of phases 3 phases
nominal switching frequency 12 kHz
dielectric strength 2830 V DC between earth and power terminals
4230 V DC between control and power terminals
motor starter type Variable speed drive
Product destination Asynchronous motors
speed range 1…10
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Supply frequency 50...60 Hz - 5...5 %
torque accuracy +/- 15 %
apparent power 1.8 kVA at 240 V
number of addresses 1…247
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
variable speed drive application selection Building - HVAC compressor for scroll
Building - HVAC fan
Building - HVAC pump
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load
transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s
Protection type Overheating protection: drive
Thermal power stage: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply overvoltage and undervoltage: drive
Line supply undervoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
With PTC probes: motor
Option card Communication card for LonWorks
Transmission rate 9600 bps or 19200 bps
frequency resolution Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
Prospective line isc 5 kA
transmission frame RTU
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Speed drive output frequency 0.5…200 Hz
Type of polarization No impedance
Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Environment
Ambient air temp for storage/transportation -25…70 °C
ip degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1
IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
IP21 conforming to EN/IEC 61800-5-1
IP21 conforming to EN/IEC 60529
IP41 on upper part conforming to EN/IEC 61800-5-1
IP41 on upper part conforming to EN/IEC 60529
operating altitude 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
<= 1000 m without derating
Range of product Altivar 212
ambient air temperature for operation -10…40 °C (without derating)
40…50 °C (with derating factor)
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental characteristics Classes 3C1 conforming to IEC 60721-3-3
Classes 3S2 conforming to IEC 60721-3-3
standards IEC 61800-3
IEC 61800-3 environments 1 category C1
EN 61800-5-1
IEC 61800-3 environments 1 category C3
EN 61800-3 environments 2 category C1
EN 61800-3
IEC 61800-3 environments 2 category C1
IEC 61800-5-1
EN 61800-3 environments 1 category C2
EN 61800-3 environments 1 category C1
IEC 61800-3 environments 2 category C3
UL Type 1
IEC 61800-3 environments 2 category C2
IEC 61800-3 environments 1 category C2
EN 61800-3 environments 2 category C2
EN 61800-3 environments 1 category C3
EN 61800-3 environments 2 category C3
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Regulation loop Adjustable PI regulator
vibration resistance 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
air flow 22 m3/h
insulation resistance >= 1 mOhm 500 V DC for 1 minute
speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Recently viewed
345,00 €
345,00 € incl. VAT
Expected in 2-4 weeks