All categories
Compare Cart

ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric

Expected in 2-4 weeks
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 0
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 1
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 2
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 3
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 4
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 5
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric - 6
ATV12H018M2 - Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric
176,09 € excl. VAT
214,83 € incl. VAT
Text About:
Variable speed drive ATV12 0.18kW 0.25hp 200..240V 1ph - Schneider Electric
214,83 €
SPECIFICATIONS
Main
product specific application Simple machine
emc filter Integrated
motor power kW 0.18 kW
Complementary
4 quadrant operation possible False
with safety function safe brake management (sbc/sbt) False
Product certifications NOM
CSA
C-Tick
UL
GOST
RCM
KC
with safety function safe operating stop (sos) False
data formats 8 bits, configurable odd, even or no parity
Handle front plate colour 143 mm
Product or component type Variable speed drive
tightening torque 0.8 N.m
[us] rated supply voltage 200...240 V - 15...10 %
Assembly style On base plate
with safety function safe programmable logic False
noise level 0 dB
marking CE
Quantity per set Set of 1
with safety function safe stop 1 (ss1) False
Analogue input number 1
Analogue output number 1
Asynchronous motor control profile Voltage/frequency ratio (V/f)
Sensorless flux vector control
Quadratic voltage/frequency ratio
width (w) 72 mm
network frequency 50...60 Hz
switching frequency 2...16 kHz adjustable
4...16 kHz with derating factor
with safety function safely limited speed (sls) False
Brake chopper integrated False
motor slip compensation Preset in factory
Adjustable
Mounting mode Cabinet mount
Braking to standstill By DC injection
Discrete input number 4
Net weight 0.7 kg
physical interface 2-wire RS 485
time constant 20 ms +/- 1 ms for reference change
base load current at high overload 1.4 A
Communication service Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Operating position Vertical +/- 10 degree
communication port protocol Modbus
Discrete output number 2
Motor power hp 0.25 hp
connector type 1 RJ45
depth 102.2 mm
line current 3.4 A at 100 V (heavy duty)
2.8 A at 120 V (heavy duty)
power dissipation in w Natural: 18.0 W
continuous output current 1.4 A at 4 kHz
maximum transient current 2.1 A during 60 s (heavy duty)
2.3 A during 2 s (heavy duty)
Pollution degree 2
linearity error +/- 0.3 % of maximum value for analogue input
nominal switching frequency 4 kHz
maximum output frequency 4 kHz
Insulation Electrical between power and control
Maximum input current 2.8 A
speed range 1…20
Maximum output voltage 240 V
Shock resistance 15 gn conforming to EN/IEC 60068-2-27 for 11 ms
Method of access Server Modbus serial
Supply frequency 50/60 Hz +/- 5 %
apparent power 0.7 kVA at 240 V (heavy duty)
number of addresses 1…247
acceleration and deceleration ramps U
Linear from 0 to 999.9 s
S
transient overtorque 150…170 % of nominal motor torque depending on drive rating and type of motor
Nominal output current 1.4 A
Protection type Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Transmission rate 9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
frequency resolution Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
Prospective line isc 1 kA
transmission frame RTU
Relative symmetric network frequency tolerance 5 %
Relay output number 1
Sampling duration 20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
Speed drive output frequency 0.5…400 Hz
Type of polarization No impedance
With safety function safe direction (sdi) False
With safety function safe position (sp) False
With safety function safe speed monitor (ssm) False
With safety function safe torque off (sto) False
With safety function safely limited position (slp) False
With sft fct safe stop 2 (ss2) False
Environment
Ambient air temp for storage/transportation -25…70 °C
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
ip degree of protection IP20
operating altitude > 1000...2000 m with current derating 1 % per 100 m
<= 1000 m without derating
Range of product Altivar 12
ambient air temperature for operation -10…40 °C without derating
40…60 °C with current derating 2.2 % per °C
electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
overvoltage category Class III
standards UL 508C
UL 618000-5-1
EN/IEC 61800-5-1
EN/IEC 61800-3
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
electromagnetic emission Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2...12 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Regulation loop Adjustable PID regulator
vibration resistance 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6