Main
Device short name
ATS48
product specific application
Heavy duty industry and pumps
Ue power supply voltage
208...690 V - 15...10 %
motor power kW
132 kW at 400 V for severe applications
132 kW at 440 V for severe applications
160 kW at 400 V for standard applications
160 kW at 440 V for standard applications
160 kW at 500 V for severe applications
160 kW at 525 V for severe applications
220 kW at 500 V for standard applications
220 kW at 525 V for standard applications
220 kW at 660 V for severe applications
250 kW at 660 V for standard applications
250 kW at 690 V for severe applications
315 kW at 690 V for standard applications
75 kW at 230 V for severe applications
90 kW at 230 V for standard applications
Complementary
Product certifications
C-Tick
NOM 117
SEPRO
CSA
UL
CCC
TCF
DNV
GOST
Handle front plate colour
380 mm
Product or component type
Soft starter
Communication data link
Serial
minimum switching current
10 mA at 6 V DC for relay outputs
marking
CE
Discrete input logic
Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
width (w)
320 mm
Analogue output type
Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
Discrete input type
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
function available
External bypass (optional)
Discrete input number
5
Net weight
18.2 kg
physical interface
RS485 multidrop
Discrete output type
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
Operating position
Vertical +/- 10 degree
communication port protocol
Modbus
Discrete output number
2
Motor power hp
100 hp at 208 V for standard applications
100 hp at 230 V for severe applications
125 hp at 230 V for standard applications
200 hp at 460 V for severe applications
250 hp at 460 V for standard applications
250 hp at 575 V for severe applications
300 hp at 575 V for standard applications
75 hp at 208 V for severe applications
connector type
1 RJ45
depth
265 mm
device connection
In the motor supply line
Product destination
Asynchronous motors
Utilisation category
AC-53A
Protection type
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Transmission rate
4800, 9600 or 19200 bps
Power supply frequency
50...60 Hz - 5...5 %
Environment
Ambient air temp for storage/transportation
-25…70 °C
operating altitude
<= 1000 m without derating
> 1000...2000 m with current derating of 2.2 % per additional 100 m
Range of product
Altistart 48
ambient air temperature for operation
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
electromagnetic compatibility
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
standards
EN/IEC 60947-4-2
relative humidity
0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3