Complementary
[ie] rated operational current
Normal duty: 590.0 A (at <40 °C)
maximum switching current
Relay outputs 2 A at 250 V AC
Relay outputs 2 A at 30 V DC
Relay outputs
Product certifications
CE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
data formats
8 bits, configurable odd, even or no parity
Handle front plate colour
670.0 mm
Product or component type
Soft starter
[uimp] rated impulse withstand voltage
6 kV
[us] control circuit voltage
110...230 V AC 50/60 Hz - 15...10 %
Communication data link
Serial
minimum switching current
10 mA at 24 V DC for relay outputs
marking
CE
CCC
UKCA
EAC
RCM
CULus
Analogue input number
1
Analogue input type
AI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number
1
Discrete input logic
Programmable digital input at State 0: < 5 V
width (w)
400.0 mm
Analogue output type
Current output AQ1: 0...20 mA or 0...10 V, impedance <500 Ohm
Discrete input type
(STOP) logic inputs, 3500 Ohm
(RUN) logic inputs, 3500 Ohm
(DI3) programmable as logic input, 3500 Ohm
(DI4) programmable as logic input, 3500 Ohm
function available
External bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Discrete input number
4
Net weight
51.4 kg
physical interface
2-wire RS 485
Discrete output type
(DQ1) programmable digital output <= 30 V
(DQ2) programmable digital output <= 30 V
Operating position
Vertical +/- 10 degree
communication port protocol
Modbus serial
Current limiting %in (5 x ie maximum)
150…700 %
Discrete output number
2
Motor power hp
150.0 hp at 208 V heavy duty
200.0 hp at 230 V normal duty
400.0 hp at 460 V normal duty
350.0 hp at 460 V heavy duty
500.0 hp at 575 V normal duty
400.0 hp at 575 V heavy duty
connector type
1 RJ45
depth
314.0 mm
Pollution degree
Level 3
Network number of phases
3 phases
device connection
In the motor supply line
To the motor delta terminals
Display screen available
True
Input compatibility
STOP: discrete input level 1 PLC conforming to EN/IEC 61131-2
RUN: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI3: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI4: discrete input level 1 PLC conforming to EN/IEC 61131-2
Product destination
Asynchronous motors
Integrated motor overload protection
True
Method of access
Slave Modbus serial
apparent power
0.125 kVA
number of addresses
0…227 for Modbus serial
Motor thermal protection class
Class 10E
Utilisation category
AC-3A
AC-53A
Protection type
Phase failure: line
Integrated thermal protection: motor
Thermal protection: starter
Current overload: motor
Underload: motor
Excessive starting time, locked rotor: motor
Motor phase loss: motor
Line supply phase loss: line
Line supply phase loss: motor
Thermal protection: motor
Option card
Communication module for Profibus DP V1
Communication module for PROFINET
Communication module for Modbus TCP/EtherNet/IP
Communication module for CANopen daisy chain
Communication module for CANopen Sub-D
Communication module for CANopen open style
Output compatibility
Open collector level 1 PLC conforming to IEC 65A-68
Power loss per device current dependent
1711.0 W
Power loss static current independent
25.0 W
relay output type
Relay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Transmission rate
1200...256000 bit/s
Power supply frequency
50...60 Hz - 20...20 %
Rated current pwr loss specification
590.0 A
transmission frame
RTU
Relay output number
3
Type of polarization
No impedance for Modbus serial
Environment
Ambient air temp for storage/transportation
-25…70 °C
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
ip degree of protection
IP00
operating altitude
<= 1000 m without derating
> 1000...4000 m with current derating 1 % per 100 m
Range of product
Altivar Soft Starter ATS480
ambient air temperature for operation
40…60 °C (with current derating of 2 % per °C)
-15…40 °C (without derating)
electromagnetic compatibility
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-11
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
standards
EN/IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Maximum acceleration under shock load (during storage)
100 m/s² at 11 ms
Maximum acceleration under shock load (during transport)
100 m/s² at 11 ms
relative humidity
0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum acceleration under vibratory load (during storage)
15 m/s² at 200...500 Hz
10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport)
15 m/s² at 200...500 Hz
10 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage)
1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport)
1.75 mm at 2...9 Hz