All categories
Compare Cart

ATS480C48Y - Altivar Soft Starter ATS480, 480 A, 208...690V AC, control supply 110...230V AC - Schneider Electric

Expected in 2-4 weeks
ATS480C48Y - Altivar Soft Starter ATS480, 480 A, 208...690V AC, control supply 110...230V AC - Schneider Electric - Altivar Soft Starter ATS480, 480 A, 208...690V AC, control supply 110...230V AC - Schneider Electric - 0
ATS480C48Y - Altivar Soft Starter ATS480, 480 A, 208...690V AC, control supply 110...230V AC - Schneider Electric
5 219,31 € excl. VAT
6 367,56 € incl. VAT
Text About:
Altivar Soft Starter ATS480, 480 A, 208...690V AC, control supply 110...230V AC - Schneider Electric
6 367,56 €
SPECIFICATIONS
Main
Device short name ATS480
product specific application Process and infrastructures
Rated current in heavy duty 410.0 A at 40 °C for heavy duty
[uc] control circuit voltage 24 V DC
Torque control True
Ue power supply voltage 208...690 V - 15...10 %
[ui] rated insulation voltage 690 V
motor power kW 132.0 kW at 230 V in the motor supply line normal duty
110.0 kW at 230 V in the motor supply line heavy duty
250.0 kW at 400 V in the motor supply line normal duty
220.0 kW at 400 V in the motor supply line heavy duty
250.0 kW at 440 V in the motor supply line normal duty
220.0 kW at 440 V in the motor supply line heavy duty
315.0 kW at 500 V in the motor supply line normal duty
250.0 kW at 500 V in the motor supply line heavy duty
315.0 kW at 525 V in the motor supply line normal duty
250.0 kW at 525 V in the motor supply line heavy duty
400.0 kW at 660 V in the motor supply line normal duty
355.0 kW at 660 V in the motor supply line heavy duty
500.0 kW at 690 V in the motor supply line normal duty
400.0 kW at 690 V in the motor supply line heavy duty
250.0 kW at 230 V to the motor delta terminals normal duty
220.0 kW at 230 V to the motor delta terminals heavy duty
355.0 kW at 400 V to the motor delta terminals normal duty
315.0 kW at 400 V to the motor delta terminals heavy duty
Complementary
[ie] rated operational current Normal duty: 480.0 A (at <40 °C)
maximum switching current Relay outputs 2 A at 250 V AC
Relay outputs 2 A at 30 V DC
Relay outputs
Product certifications CE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
data formats 8 bits, configurable odd, even or no parity
Handle front plate colour 670.0 mm
Product or component type Soft starter
[uimp] rated impulse withstand voltage 6 kV
[us] control circuit voltage 110...230 V AC 50/60 Hz - 15...10 %
Communication data link Serial
minimum switching current 10 mA at 24 V DC for relay outputs
marking CE
CCC
UKCA
EAC
RCM
CULus
Analogue input number 1
Analogue input type AI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number 1
Discrete input logic Programmable digital input at State 0: < 5 V
width (w) 400.0 mm
Analogue output type Current output AQ1: 0...20 mA or 0...10 V, impedance <500 Ohm
Discrete input type (STOP) logic inputs, 3500 Ohm
(RUN) logic inputs, 3500 Ohm
(DI3) programmable as logic input, 3500 Ohm
(DI4) programmable as logic input, 3500 Ohm
function available External bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Discrete input number 4
Net weight 51.4 kg
physical interface 2-wire RS 485
Discrete output type (DQ1) programmable digital output <= 30 V
(DQ2) programmable digital output <= 30 V
Operating position Vertical +/- 10 degree
communication port protocol Modbus serial
Current limiting %in (5 x ie maximum) 150…700 %
Discrete output number 2
Motor power hp 150.0 hp at 208 V normal duty
125.0 hp at 208 V heavy duty
150.0 hp at 230 V heavy duty
350.0 hp at 460 V normal duty
300.0 hp at 460 V heavy duty
400.0 hp at 575 V normal duty
350.0 hp at 575 V heavy duty
connector type 1 RJ45
depth 314.0 mm
Pollution degree Level 3
Network number of phases 3 phases
device connection In the motor supply line
To the motor delta terminals
Display screen available True
Input compatibility STOP: discrete input level 1 PLC conforming to EN/IEC 61131-2
RUN: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI3: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI4: discrete input level 1 PLC conforming to EN/IEC 61131-2
Product destination Asynchronous motors
Integrated motor overload protection True
Method of access Slave Modbus serial
apparent power 0.125 kVA
number of addresses 0…227 for Modbus serial
Motor thermal protection class Class 10E
Utilisation category AC-3A
AC-53A
Protection type Phase failure: line
Integrated thermal protection: motor
Thermal protection: starter
Current overload: motor
Underload: motor
Excessive starting time, locked rotor: motor
Motor phase loss: motor
Line supply phase loss: line
Line supply phase loss: motor
Thermal protection: motor
Option card Communication module for Profibus DP V1
Communication module for PROFINET
Communication module for Modbus TCP/EtherNet/IP
Communication module for CANopen daisy chain
Communication module for CANopen Sub-D
Communication module for CANopen open style
Output compatibility Open collector level 1 PLC conforming to IEC 65A-68
Power loss per device current dependent 1366.0 W
Power loss static current independent 25.0 W
relay output type Relay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Transmission rate 1200...256000 bit/s
Power supply frequency 50...60 Hz - 20...20 %
Rated current pwr loss specification 480.0 A
transmission frame RTU
Relay output number 3
Type of polarization No impedance for Modbus serial
Environment
Ambient air temp for storage/transportation -25…70 °C
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
ip degree of protection IP00
operating altitude <= 1000 m without derating
> 1000...4000 m with current derating 1 % per 100 m
Range of product Altivar Soft Starter ATS480
ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C)
-15…40 °C (without derating)
electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-11
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
standards EN/IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms
relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
Maximum acceleration under vibratory load (during storage) 15 m/s² at 200...500 Hz
10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport) 15 m/s² at 200...500 Hz
10 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage) 1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport) 1.75 mm at 2...9 Hz
Recently viewed
5 219,31 € excl. VAT
6 367,56 € incl. VAT
Expected in 2-4 weeks