Complementary
control circuit consumption
20 W
maximum switching current
5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs
2 A 250 V AC inductive 0.4 20 ms relay outputs
2 A 30 V DC inductive 7 ms relay outputs
Product certifications
CCC
GOST
C-Tick
CSA
UL
Handle front plate colour
295 mm
Product or component type
Soft starter
[us] rated supply voltage
230...600 V - 15...10 %
Assembly style
With heat sink
Communication data link
Serial
minimum switching current
100 mA at 12 V DC (relay outputs)
noise level
45 dB
output current
0.4...1 Icl adjustable
marking
CE
ptc probe input
750 Ohm
Discrete input logic
Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
width (w)
145 mm
Discrete input type
(LI1, LI2, LI3) logic, 5 mA 4.3 kOhm
function available
Internal bypass
network frequency
45...66 Hz
supply voltage limits
195…660 V
Discrete input voltage
24 V <= 30 V
Discrete input number
3
Net weight
12 kg
physical interface
RS485 multidrop
Discrete output type
Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Operating position
Vertical +/- 10 degree
communication port protocol
Modbus
Discrete output number
2
connector type
1 RJ45
depth
207 mm
power dissipation in w
66 W for standard applications
Motor power range ac-3
55…100 kW at 480…500 V 3 phases
15…25 kW at 200…240 V 3 phases
30…50 kW at 380…440 V 3 phases
Pollution degree
Level 2 conforming to IEC 60664-1
Installed device
31
Network number of phases
3 phases
device connection
In the motor supply line
motor starter type
Soft starter
Product destination
Asynchronous motors
Shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
Supply frequency
50...60 Hz - 10...10 %
Type of start
Start with torque control (current limited to 3.5 In)
Utilisation category
AC-53A
Protection type
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Transmission rate
4800, 9600 or 19200 bps
Type of cooling
Forced convection
Environment
Ambient air temp for storage/transportation
-25…70 °C
ip degree of protection
IP20
operating altitude
<= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m
Range of product
Altistart 22
ambient air temperature for operation
-10…40 °C (without derating)
40…60 °C (with current derating 2.2 % per °C)
electromagnetic compatibility
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
standards
EN/IEC 60947-4-2
relative humidity
0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
vibration resistance
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6