All categories
Compare Cart

ATS22D32S6U - SoftstarterATS22control110Vpower 208V(7.5hp)/230V(10hp)/460V(20hp)/575V(25hp) - Schneider Electric

Expected in 2-4 weeks
ATS22D32S6U - SoftstarterATS22control110Vpower 208V(7.5hp)/230V(10hp)/460V(20hp)/575V(25hp) - Schneider Electric - SoftstarterATS22control110Vpower 208V(7.5hp)/230V(10hp)/460V(20hp)/575V(25hp) - Schneider Electric - 0
ATS22D32S6U - SoftstarterATS22control110Vpower 208V(7.5hp)/230V(10hp)/460V(20hp)/575V(25hp) - Schneider Electric
744,96 € excl. VAT
908,86 € incl. VAT
Text About:
SoftstarterATS22control110Vpower 208V(7.5hp)/230V(10hp)/460V(20hp)/575V(25hp) - Schneider Electric
908,86 €
SPECIFICATIONS
Main
Icl starter rating 32 A for connection in the motor supply line for standard applications
product specific application Pumps and fans
[uc] control circuit voltage 110 V - 15...10 % 50/60 Hz
factory setting current 27 A
component name ATS22
Complementary
control circuit consumption 20 W
maximum switching current 5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs
2 A 250 V AC inductive 0.4 20 ms relay outputs
2 A 30 V DC inductive 7 ms relay outputs
Product certifications CCC
CSA
GOST
C-Tick
UL
Handle front plate colour 265 mm
Product or component type Soft starter
[us] rated supply voltage 208...600 V - 15...10 %
Assembly style With heat sink
Communication data link Serial
minimum switching current 100 mA at 12 V DC (relay outputs)
noise level 45 dB
output current 0.4...1 Icl adjustable
marking CE
ptc probe input 750 Ohm
Discrete input logic Positive logic LI1, LI2, LI3 at State 0: < 20 V and <= 15 mA at State 1: > 79 V, <= 2 mA
width (w) 130 mm
Discrete input type (LI1, LI2, LI3) logic, 5 mA 20 kOhm
function available Internal bypass
network frequency 45...66 Hz
supply voltage limits 177…660 V
Discrete input voltage 110 V <= 121 V
Discrete input number 3
Net weight 7 kg
physical interface RS485 multidrop
Discrete output type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Operating position Vertical +/- 10 degree
communication port protocol Modbus
Discrete output number 2
Motor power hp 10 hp 230 V
20 hp 460 V
25 hp 575 V
7.5 hp 208 V
connector type 1 RJ45
depth 169 mm
power dissipation in w 44 W for standard applications
Pollution degree Level 2 conforming to IEC 60664-1
Installed device 31
Network number of phases 3 phases
device connection In the motor supply line
Product destination Asynchronous motors
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Supply frequency 50...60 Hz - 10...10 %
Type of start Start with torque control (current limited to 3.5 In)
Utilisation category AC-53A
Protection type Phase failure: line
Thermal protection: motor
Thermal protection: starter
Transmission rate 4800, 9600 or 19200 bps
Type of cooling Forced convection
Environment
Ambient air temp for storage/transportation -25…70 °C
ip degree of protection IP20
operating altitude <= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m
Range of product Altistart 22
ambient air temperature for operation -10…40 °C (without derating)
40…60 °C (with current derating 2.2 % per °C)
electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
standards EN/IEC 60947-4-2
relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
vibration resistance 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6
Recently viewed
744,96 € excl. VAT
908,86 € incl. VAT
Expected in 2-4 weeks