All categories
Compare Cart

ABLP1A24062 - Modicon ABL - switching power supply - 6.2A - 100 to 240Vac single phase - 24Vdc - Schneider Electric

Expected in 2-4 weeks EAN: 3606481500298
ABLP1A24062 - Modicon ABL - switching power supply - 6.2A - 100 to 240Vac single phase - 24Vdc - Schneider Electric - Modicon ABL - switching power supply - 6.2A - 100 to 240Vac single phase - 24Vdc - Schneider Electric - 0
EAN: 3606481500298
ABLP1A24062 - Modicon ABL - switching power supply - 6.2A - 100 to 240Vac single phase - 24Vdc - Schneider Electric
126,74 €
126,74 € incl. VAT
Text About:
Modicon ABL - switching power supply - 6.2A - 100 to 240Vac single phase - 24Vdc - Schneider Electric
126,74 €
SPECIFICATIONS
Main
power supply module output current 6,25 A
product range Alimentation Modicon
type of product or equipment Alimentation puissance
nominal power in w 150 W
rated input voltage 100...120 V CA monophasé
200...240 V CA monophasé
kind of power supply Mode commutation régulée
optional variant Montage sur panneau
Complementary
18 mm pitches 0.55 at 115 V AC
0.45 at 230 V AC
feed SELV se conformer à EN/CEI 60950-1
SELV se conformer à EN/CEI 60204-1
SELV se conformer à CEI 60364-4-41
power consumption < 3,2 A 115 V CA
< 1,9 A 230 V CA
output coupling Parallèle
Série
Handle front plate colour 30 mm
maximum leakage current 1 mA 240 V CA
case material Aluminium
inrush current 35 A à 115 V
70 A à 230 V
expected capacitor life 10 année(s)
product weight 0,36 kg
starting with capacitive loads 7000 µF
led status 1 LED (vert) tension de sortie
connection mode Connexion à vis: 0,75...2,5 mm², (AWG 18 à AWG 14) sans embout de câble
Connexion à vis: 0,75 à 1,5 mm², (AWG 18...AWG 16) avec virole d'extrémité de câble
nominal network frequency 50…60 Hz
output voltage 24 V CC
width (w) 97 mm
input voltage limits 90...132 V CA
170...264 V CA
line and load regulation < 0,5 % network 0 to 100 % load at 25 °C
< 1 % network full voltage range in line at 25 °C
residual ripple < 170 mV
depth 159 mm
mounting bracket Top hat type TH35-15 rail se conformer à CEI 60715
Top hat type TH35-7.5 rail se conformer à CEI 60715
DIN double profil rail
montage sur panneau
power dissipation in w 29 W
yield 88,8 % à 230 V CA
output voltage adjustment 21,6…26,4 V
compatible network system TN
TT
IT
mataining time > 20 ms 115 V CA
> 40 ms 230 V CA
start-up time < 500 ms
mean time between failures (mtbf) 700000 H at 25 °C, pleine charge conforming to SR 332
dielectric strength 3750 V CA avec input to output
output protection type Contre la surcharge et les courts-circuits, protection technologique : remise à zéro automatique
Contre la surchauffe, protection technologique : remise à zéro manuelle
Contre la surtension, protection technologique : remise à zéro manuelle
input protection type Fusible intégré (non interchangeable) 4 A
Environment
degree of pollution 2
environment characteristic 3M4 se conformer à CEI 60721-3-3
ip degree of protection IP10
operating altitude 5000 m
product certificates CE
CULus
EAC
RCM
Schéma CB
KC
ambient air temperature for operation -30…-25 °C with current derating of 4 % per °C mounting position B, G < 2000 m
-25…50 °C sans déclassement mounting position B, G < 2000 m
50…70 °C avec réduction de courant de 2 % par °C mounting position B, G < 2000 m
class of protection against electric shock Classe I
standards EN 62368-1
EN/CEI 61010-1
EN 61010-2-201
EN/CEI 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
UL 62368-1
UL 61010-1
UL 61010-2-201
CSA C22.2 No 62368-1
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
CEI 60335-1
EN/CEI 62368-1
mechanical shock resistance 100 m/s² pour 11 ms
electromagnetic emission Émissions conduites se conformer à EN 61000-6-3
Émissions rayonnées se conformer à EN 61000-6-4
vibration resistance 3 mm (f= 2…9 Hz) se conformer à CEI 60068-2-6
10 m/s² (f= 9…200 Hz) se conformer à CEI 60068-2-6
electromagnetic immunity Immunité aux décharges électrostatiques - niveau de test : 6 kV (décharge par contact) se conformer à EN/CEI 61000-4-2
Immunité aux décharges électrostatiques - niveau de test : 9 kV (décharge dans l'air) se conformer à EN/CEI 61000-4-2
Immunité aux perturbations RF transmises par conduction - niveau de test : 10 V/m (80 MHz...2 GHz) se conformer à EN/CEI 61000-4-3
Immunité aux perturbations RF transmises par conduction - niveau de test : 5 V/m (2…2,7 GHz) se conformer à EN/CEI 61000-4-3
Immunité aux perturbations RF transmises par conduction - niveau de test : 3 V/m (2.7...6 GHz) se conformer à EN/CEI 61000-4-3
Immunité aux transitoires rapides - niveau de test : 4 kV (sur entrée-sortie) se conformer à EN/CEI 61000-4-4
Test d’immunité aux surtensions - niveau de test : 3 kV (entre alimentation et terre) se conformer à EN/CEI 61000-4-5
Test d’immunité aux surtensions - niveau de test : 1,5 kV (entre phases) se conformer à EN/CEI 61000-4-5
Immunité aux perturbations RF transmises par conduction - niveau de test : 10 V (0,15 à 80 MHz) se conformer à EN/CEI 61000-4-6
Immunité aux champs magnétiques - niveau de test : 30 A/m (50 à 60 Hz) se conformer à EN/CEI 61000-4-8
Immunité aux chutes de tension se conformer à EN/CEI 61000-4-11
Émission de champ de perturbation se conformer à EN 55016-2-3
Limitation d'émission de courant harmonique se conformer à EN 61000-3-2
Émission de perturbation transmise par conduction se conformer à EN 55016-1-2
Émission de perturbation transmise par conduction se conformer à EN 55016-2-1