SPECIFICATIONS
Main
power supply module output current 0,625 A
product range Alimentation Modicon
type of product or equipment Alimentation puissance
nominal power in w 15 W
rated input voltage 100...240 V CA monophasé
100...240 V CA 2 phases
kind of power supply Mode commutation régulée
optional variant Modulaire
Complementary
18 mm pitches 0.51 at 115 V AC
0.40 at 230 V AC
feed SELV se conformer à EN/CEI 60950-1
SELV se conformer à EN/CEI 60204-1
SELV se conformer à CEI 60364-4-41
power consumption < 0,4 A 115 V CA
< 0,25 A 230 V CA
output coupling Série
Handle front plate colour 91 mm
maximum leakage current 0,25 mA 240 V CA
case material Plastique
inrush current 15 A à 115 V
30 A à 230 V
expected capacitor life 10 année(s)
product weight 0,101 kg
starting with capacitive loads 3000 µF
led status 1 LED (vert) tension de sortie
connection mode Connexion à vis: 0,5…1,5 mm², (4 x 1,5 mm² + 2 x 1 mm² + 2 x 0,14 mm²) sans embout de câble pour entrée/sortie
Connexion à vis: 0,5 à 1 mm², (AWG 20 à AWG 18) avec virole d'extrémité de câble pour entrée/sortie
nominal network frequency 50…60 Hz
output voltage 24 V CC
width (w) 18 mm
input voltage limits 90 à 264 V CA
line and load regulation < 0,5 % network in line
< 1 % network 0 to 100 % load
residual ripple < 100 mV
depth 55,6 mm
mounting bracket Top hat type TH35-15 rail se conformer à CEI 60715
Top hat type TH35-7.5 rail se conformer à CEI 60715
DIN double profil rail
montage sur panneau
power dissipation in w 3,5 W
yield 81 % à 115 V CA
81 % à 230 V CA
compatible network system TN
TT
IT
mataining time > 10 ms 115 V CA
> 60 ms 230 V CA
start-up time < 2 s
mean time between failures (mtbf) 3000000 H at 25 °C, pleine charge
1000000 H at 55 °C, charge 80%
dielectric strength 3000 V CA entrée/sortie
output protection type Contre la surcharge et les courts-circuits, protection technologique : remise à zéro automatique
Contre la surchauffe, protection technologique : remise à zéro manuelle
Contre la surtension, protection technologique : remise à zéro manuelle
input protection type Fusible intégré (non interchangeable) 3,15 A
Protection externe (recommandée) 20 A Curve B
Protection externe (recommandée) 20 A Curve C
Protection externe (recommandée) 2 A Curve B
Protection externe (recommandée) 2 A Curve C
Environment
degree of pollution 2
ip degree of protection IP20
operating altitude < 2000 m surtension catégorie III
2000 m...5000 m surtension catégorie II
product certificates CE
Répertorié cUL
Reconnu cUL
RCM
Schéma CB
EAC
KC
NEC: classe 2
ambient air temperature for operation -25…55 °C sans réduction de courant mounting position A < 2000 m
55…70 °C avec réduction de courant de 2,67 % par °C mounting position A < 2000 m
class of protection against electric shock Classe II sans connexion PE
standards EN 62368-1
EN/CEI 61010-1
EN 61010-2-201
EN/CEI 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
UL 62368-1
UL 61010-1
UL 61010-2-201
CSA C22.2 No 62368-1
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
EN/CEI 62368-1
mechanical shock resistance 100 m/s² pour 11 ms
electromagnetic emission Émissions conduites se conformer à EN 61000-6-3
Émissions rayonnées se conformer à EN 61000-6-4
vibration resistance 3 mm (f= 2…9 Hz) se conformer à CEI 60721-3-3
10 m/s² (f= 9…200 Hz) se conformer à CEI 60721-3-3
electromagnetic immunity Immunité aux décharges électrostatiques - niveau de test : 6 kV (décharge par contact) se conformer à EN/CEI 61000-4-2
Immunité aux décharges électrostatiques - niveau de test : 9 kV (décharge dans l'air) se conformer à EN/CEI 61000-4-2
Test d'immunité de champ électromagnétique - niveau de test : 10 V/m (80 MHz...2 GHz) se conformer à EN/CEI 61000-4-3
Test d'immunité de champ électromagnétique - niveau de test : 5 V/m (2…2,7 GHz) se conformer à EN/CEI 61000-4-3
Test d'immunité de champ électromagnétique - niveau de test : 3 V/m (2.7...6 GHz) se conformer à EN/CEI 61000-4-3
Immunité aux transitoires rapides - niveau de test : 4 kV (sur entrée-sortie) se conformer à EN/CEI 61000-4-4
Test d’immunité aux surtensions - niveau de test : 3 kV (entre alimentation et terre) se conformer à EN/CEI 61000-4-5
Test d’immunité aux surtensions - niveau de test : 1,5 kV (entre phases) se conformer à EN/CEI 61000-4-5
Immunité aux perturbations transmises par conduction - niveau de test : 10 Vrms (0,15 à 80 MHz) se conformer à EN/CEI 61000-4-6
Immunité aux champs magnétiques - niveau de test : 30 A/m (50 à 60 Hz) se conformer à EN/CEI 61000-4-8
Immunité aux chutes de tension - niveau de test : 100 % (1 cycle) se conformer à EN/CEI 61000-4-11
Immunité aux chutes de tension - niveau de test : 60 % (10 cycles) se conformer à EN/CEI 61000-4-11
Immunité aux chutes de tension - niveau de test : 30 % (25 cycles) se conformer à EN/CEI 61000-4-11
Émission de champ de perturbation se conformer à EN 55016-2-3
Limitation d'émission de courant harmonique se conformer à EN 61000-3-2
Émission de perturbation transmise par conduction se conformer à EN 55016-1-2
Émission de perturbation transmise par conduction se conformer à EN 55016-2-1