All categories
Compare Cart

A9Z64225 - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 25A, B-SI type, 300mA, double terminal - Schneider Electric

Expected in 2-4 weeks
A9Z64225 - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 25A, B-SI type, 300mA, double terminal - Schneider Electric - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 25A, B-SI type, 300mA, double terminal - Schneider Electric - 0
A9Z64225 - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 25A, B-SI type, 300mA, double terminal - Schneider Electric
240,52 € excl. VAT
293,43 € incl. VAT
Text About:
Residual current circuit breaker (RCCB), Acti9 iID, 2P, 25A, B-SI type, 300mA, double terminal - Schneider Electric
293,43 €
SPECIFICATIONS
Main
Device short name iID
Device location in system Outgoer
Group incomer
Range Acti9
Earth-leakage protection class Type B-SI (Super Immunised)
Neutral position Left
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 300 mA
Product Name Acti9 iID
[ui] rated insulation voltage 250 V
Complementary
9 mm pitches 8
[in] rated current 25 A
[ue] rated operational voltage 230 V AC 50 Hz
[ics] rated service breaking capacity Idm 1500 A
Im 1500 A
Control type Toggle
Product certifications CCC
KC
Handle front plate colour 88 mm
Product or component type Residual current circuit breaker (RCCB)
tightening torque 3.5 N.m top or bottom
[uimp] rated impulse withstand voltage 6 kV
Connections - terminals Double terminal front 1…35 mm² rigid
Double terminal front 1…25 mm² flexible
Double terminal front 1…25 mm² flexible with ferrule
Double terminal back 1…25 mm² rigid
Double terminal back 1…16 mm² flexible
Double terminal back 1…16 mm² flexible with ferrule
Locking options description Padlocking device
Contact position indication Yes
Device application Photovoltaic
Lift
width (w) 72 mm
network frequency 50 Hz
Colour White
Ik degree of protection IK05
Local signalling ON/OFF indication
LED (green) for presence of voltage
Trip indicator
Mounting mode Clip-on
Net weight 350 g
wire stripping length 14 mm for top or bottom connection
Mounting support DIN rail
depth 79 mm
mechanical durability 20000 cycles
electrical durability 15000 cycles
Network type AC
Pollution degree 3
residual current tripping technology Voltage independent
Rated conditional short-circuit current 10 kA
Poles description 2P
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
operating altitude 0...2000 m
ambient air temperature for operation -25…60 °C
electromagnetic compatibility 8/20 µs impulse withstand, 3 kA conforming to EN/IEC 61008-1
overvoltage category IV
standards IEC 61008-2-1
IEC/EN 62423
EN 61008-2-1
quality labels VDE
NF
IMQ
KEMA
Recently viewed
240,52 € excl. VAT
293,43 € incl. VAT
Expected in 2-4 weeks