All categories
Compare Cart

A9Z35240 - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 40A, A-SI type, 300mA, selective, double terminal - Schneider Electric

Expected in 2-4 weeks
A9Z35240 - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 40A, A-SI type, 300mA, selective, double terminal - Schneider Electric - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 40A, A-SI type, 300mA, selective, double terminal - Schneider Electric - 0
A9Z35240 - Residual current circuit breaker (RCCB), Acti9 iID, 2P, 40A, A-SI type, 300mA, selective, double terminal - Schneider Electric
76,98 € excl. VAT
93,92 € incl. VAT
Text About:
Residual current circuit breaker (RCCB), Acti9 iID, 2P, 40A, A-SI type, 300mA, selective, double terminal - Schneider Electric
93,92 €
SPECIFICATIONS
Main
Device short name iID
Range Acti9
Earth-leakage protection class Type A-SI (Super Immunised)
Neutral position Left
Earth-leakage protection time delay Selective
Earth-leakage sensitivity 300 mA
Product Name Acti9 iID
[ui] rated insulation voltage 500 V AC 50/60 Hz
Complementary
9 mm pitches 4
[in] rated current 40 A
[ue] rated operational voltage 220...240 V AC 50/60 Hz
[ics] rated service breaking capacity Idm 1500 A
Im 1500 A
Control type Toggle
Handle front plate colour 91 mm
Product or component type Residual current circuit breaker (RCCB)
tightening torque 3.5 N.m top or bottom
[uimp] rated impulse withstand voltage 6 kV
Connections - terminals Double terminal front 1…35 mm² rigid
Double terminal front 1…25 mm² flexible
Double terminal front 1…25 mm² flexible with ferrule
Double terminal back 1…25 mm² rigid
Double terminal back 1…16 mm² flexible
Double terminal back 1…16 mm² flexible with ferrule
Locking options description Padlocking device
Contact position indication Yes
width (w) 36 mm
network frequency 50/60 Hz
Colour White
Mounting mode Clip-on
Net weight 0.21 kg
wire stripping length 14 mm for top or bottom connection
Mounting support DIN rail
depth 73 mm
mechanical durability 20000 cycles
electrical durability AC-1: 15000 cycles
Network type AC
Pollution degree 3
residual current tripping technology Voltage independent
Rated conditional short-circuit current 10 kA
Poles description 2P
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
ambient air temperature for operation -25…60 °C
electromagnetic compatibility 8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1
standards EN/IEC 61008-1
EN/IEC 61008-2-1