SPECIFICATIONS
Additional Information
curve C
Main
Device short name iDPN Vigi
Device location in system Outgoer
Range Clario
circuit breaker application Distribution
Neutral position Left
Number of protected poles 1
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 30 mA
Product Name IDPN Vigi
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 440 V AC conforming to EN 61009
Complementary
9 mm pitches 4
product compatibility Single terminal
[in] rated current 25 A at 30 °C
[ue] rated operational voltage 230 V AC 50 Hz between phase and neutral
[ics] rated service breaking capacity 4500 A at 230 V AC 50 Hz conforming to EN 61009
Control type Toggle
Handle front plate colour 81 mm
Product or component type Earth leakage circuit breaker
tightening torque 2 N.m
[uimp] rated impulse withstand voltage 4 kV conforming to EN 61009
Comb busbar and distribution block compatibility Upstream: Clario
Connections - terminals Cable (downstream) 0.75…16 mm² rigid
Cable (downstream) 0.33…10 mm² flexible
Cable (upstream) 0.75…16 mm² rigid
Cable (upstream) 0.33…10 mm² flexible
Contact position indication Yes
width (w) 36 mm
network frequency 50 Hz
Colour White
Local signalling ON/OFF indication
Net weight 210 g
wire stripping length 13 mm
Earth-leakage protection Integrated
Mounting support DIN rail
depth 71 mm
mechanical durability 20000 cycles
electrical durability 10000 cycles conforming to EN 61009
magnetic trip limit 5...10 x In
Network type AC
Pollution degree 3 conforming to EN 61009
Limitation class 3 conforming to EN 61009
residual current tripping technology Voltage independent
Suitability for isolation Yes
Poles description 1P + N
Environment
Ambient air temp for storage/transportation -40…60 °C
ip degree of protection IP20 conforming to IEC 60529
operating altitude 2000 m
ambient air temperature for operation -5…60 °C
standards EN/IEC 61009-2-1
EN/IEC 61009-1
Tropicalisation 2 conforming to IEC 60068-1
relative humidity 95 % at 55 °C