SPECIFICATIONS
Additional Information
curve B
Main
Device short name iDPN N Vigi
Device location in system Outgoer
Range Acti9
Earth-leakage protection class Type A
Neutral position Left
Number of protected poles 1
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 30 mA
Product Name Acti9 iDPN Vigi
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 400 V AC 50 Hz
Complementary
9 mm pitches 4
[in] rated current 6 A
[ue] rated operational voltage 220...240 V AC 50 Hz
[ics] rated service breaking capacity 6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Control type Toggle
Product certifications VDE
KEMA
Connection pitch 9 mm between phase and neutral
Handle front plate colour 85 mm
Product or component type Residual current breaker with overcurrent protection (RCBO)
tightening torque 2 N.m top or bottom
[uimp] rated impulse withstand voltage 4 kV
Comb busbar and distribution block compatibility Top or bottom: YES
Connections - terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Locking options description Padlocking device
Contact position indication Yes
Device application Distribution
width (w) 36 mm
network frequency 50 Hz
Colour White
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Net weight 125 g
wire stripping length 15 mm for top or bottom connection
Earth-leakage protection Integrated
Mounting support DIN rail
depth 73 mm
mechanical durability 20000 cycles
electrical durability 20000 cycles
magnetic trip limit 3...5 x In
Network type AC
Pollution degree 3
Limitation class 3 conforming to EN/IEC 61009-2-1
residual current tripping technology Voltage independent
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 1P + N
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
ambient air temperature for operation -25…60 °C
electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
overvoltage category III conforming to IEC 60364
standards EN/IEC 61009-2-1
Tropicalisation 2 conforming to IEC 60068-1
relative humidity 95 % at 55 °C