SPECIFICATIONS
Additional Information
curve C
Main
Device short name DPN N Vigi
Device location in system Outgoer
Range Acti9
circuit breaker application Distribution
Neutral position Left
Number of protected poles 1
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 30 mA
Product Name DPN Vigi
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 400 V AC conforming to EN 61009
Complementary
9 mm pitches 4
[in] rated current 25 A at 30 °C
[ue] rated operational voltage 230 V AC
[ics] rated service breaking capacity 6000 A at 230 V AC 50/60 Hz conforming to EN 61009
Control type Toggle
Product or component type Earth leakage circuit breaker
[uimp] rated impulse withstand voltage 4 kV conforming to EN 61009
Connections - terminals Tunnel type terminals1 cable(s) 10 mm² flexible
Tunnel type terminals1 cable(s) 16 mm² rigid
Contact position indication Yes
Colour White
Local signalling ON/OFF indication
Net weight 0.19 kg
Earth-leakage protection Integrated
Mounting support DIN rail
mechanical durability 20000 cycles
electrical durability 10000 cycles conforming to IEC 61009
magnetic trip limit 5...10 x In
Network type AC
Pollution degree 3 conforming to EN 61009
Limitation class 3 conforming to EN 61009
residual current tripping technology Voltage independent
Poles description 1P + N
Environment
Ambient air temp for storage/transportation -40…60 °C
operating altitude 2000 m
ambient air temperature for operation -5…60 °C
overvoltage category III
standards EN/IEC 61009-1
EN/IEC 61009-2-1
Tropicalisation 2 conforming to EN 61009
relative humidity 95 % at 55 °C