Main
Concentrator compatibility
Acti9 PowerTag Link C
Acti9 PowerTag Link
Acti9 PowerTag Link HD
Harmony Hub
EcoStruxure Panel Server Universal
EcoStruxure Panel Server Advanced
PrismaSet Active
product specific application
Energy management
Overload alarm
Power factor
Load monitoring
Circuit monitoring
Event management
Voltage loss with measured current at voltage loss
Product Name
PowerTag R600
cable length
1 m for sensor
Starting current
400 mA
poles
3P
3P + N
Complementary
[ib] basic current
100 A
range compatibility
Acti9
TeSys
Cable cross section
1 rigid cable 0.2…1.5 mm² without cable end
1 stranded cable 0.2…2.5 mm² without cable end
1 stranded cable 0.25…1.5 mm² with cable end
Handle front plate colour
Base unit: 105 mm
Product or component type
Energy sensor
accuracy class
Class 1 active energy conforming to IEC 61557-12
Class 2 reactive energy conforming to IEC 61557-12
Class 2 apparent energy conforming to IEC 61557-12
Class 1 active power conforming to IEC 61557-12
Class 2 reactive power conforming to IEC 61557-12
Class 2 apparent power conforming to IEC 61557-12
Class 1 current conforming to IEC 61557-12
Class 0.5 voltage conforming to IEC 61557-12
Class 1 power factor conforming to IEC 61557-12
Class 0.5 frequency conforming to IEC 61557-12
mounting location
Top or bottom
Current sensor diameter
Closed: 100 mm
type of measurement
Active and reactive energy
Apparent energy
Active and reactive power
Apparent power
Current
Voltage
Power factor
Internal temperature
Frequency
Electrical connection (voltage sensing & power supply)
Removable spring terminal block
Emission power
10 mW
width (w)
Base unit: 18 mm
maximum current [imax]
600 A
network frequency
50 Hz
60 Hz
Colour
White (RAL 9003)
Ik degree of protection
IK05
Mounting mode
Clip-on (DIN rail)
Saturation current
1200 A
Maximum power consumption
3 VA
wire stripping length
11 mm
Mounting support
Busbar
Cables
depth
Base unit: 67.5 mm
Transmission support medium
Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4
Pollution degree
3
Number of 9mm pitches on din rail
2
Metering type
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at total per phase
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at partial per phase
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase total
Active energy E -a- IN/OUT 0...281 x 10exp(9) kWh at 3-phase partial
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at total per phase
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at partial per phase
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase total
Reactive energy E -rA- IN/OUT 0...281 x 10exp(9) kVARh at 3-phase partial
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at total per phase
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at partial per phase
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase total
Apparent energy E -apA- 0...281 x 10exp(9) kVAh at 3-phase partial
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Current I1, I2, I3
Calculated neutral current
Voltage U12, U23, U31
Voltage V1N, V2N, V3N
Frequency 45...65 Hz
Power factor at per phase
Power factor at total
Product destination
Switchboard
supply voltage
100...277 V AC, +/- 20 %, phase to neutral
173...480 V AC, +/- 20 %, phase to phase
Environment
Ambient air temp for storage/transportation
-40…85 °C
Directives
2014/53/EU - radio equipment directive
ip degree of protection
IP20 conforming to IEC 60529
operating altitude
0...2000 m
Range of product
PowerLogic
ambient air temperature for operation
-25…70 °C
electromagnetic compatibility
Industrial electromagnetic environment conforming to IEC 61326-1
Radiated EMC conforming to ETSI EN 301 489-17
Electromagnetic emission conforming to IEC 62311
Environmental characteristics
Indoor use
overvoltage category
IV conforming to IEC 61010-1
standards
IEC 61557-12
IEC 61010-1
ETSI EN 301 487-1
IEC 61010-2-030
IEC 61326-1
ETSI EN 300 328
Maximum conductor temperature
105 °C
measurement category
Category IV conforming to IEC 61010-2-030
quality labels
CE
relative humidity
0…95 % at 55 °C conforming to IEC 60721-3-3
vibration resistance
3M4 conforming to IEC 60721-3-3