All categories
Compare Cart

A9F04103 - Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 3A, C curve, 6000A (IEC 60898-1), 50kA (IEC 60947-2), double term. - Schneider Electric

Expected in 2-4 weeks
A9F04103 - Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 3A, C curve, 6000A (IEC 60898-1), 50kA (IEC 60947-2), double term. - Schneider Electric - Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 3A, C curve, 6000A (IEC 60898-1), 50kA (IEC 60947-2), double term. - Schneider Electric - 0
A9F04103 - Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 3A, C curve, 6000A (IEC 60898-1), 50kA (IEC 60947-2), double term. - Schneider Electric
12,90 € excl. VAT
15,74 € incl. VAT
Text About:
Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 3A, C curve, 6000A (IEC 60898-1), 50kA (IEC 60947-2), double term. - Schneider Electric
15,74 €
SPECIFICATIONS
Additional Information
curve C
Main
Device short name IC60N
Range Acti9
Number of protected poles 1
Product Name Acti9 iC60
Trip unit technology Thermal-magnetic
[ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
Complementary
9 mm pitches 2
[in] rated current 3 A
[ics] rated service breaking capacity 50 kA 100 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Control type Toggle
Handle front plate colour 91 mm
Product or component type Miniature circuit-breaker
tightening torque 2 N.m top or bottom
[uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Connections - terminals Double terminal (top or bottom) 1…25 mm² rigid
Double terminal (top or bottom) 1…16 mm² flexible
Contact position indication Yes
Device application Distribution
width (w) 18 mm
network frequency 50/60 Hz
Colour White
Local signalling Trip indicator
Net weight 0.125 kg
wire stripping length 14 mm for top or bottom connection
Earth-leakage protection Without
Mounting support DIN rail
depth 78.5 mm
mechanical durability 20000 cycles
electrical durability 10000 cycles
magnetic trip limit 8 x In +/- 20 %
Network type DC
AC
Pollution degree 3
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Poles description 1P
Utilisation category Category A conforming to EN 60898-1
Category A conforming to IEC 60898-1
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
ambient air temperature for operation -35…70 °C
overvoltage category IV
standards IEC 60898-1
EN 60898-1
EN 60947-2
IEC 60947-2
Tropicalisation 2
relative humidity 95 % at 55 °C
Recently viewed
12,90 € excl. VAT
15,74 € incl. VAT
Expected in 2-4 weeks